Start up operation – Windsor Saber Compact 22 User Manual

Page 11

Advertising
background image

English

11

Emergency stop button is unlocked
(when the main cable is inserted):
– the charging process is started
– the battery indicator lamp is yellow and

flashing

Î

Add distilled water one hour before the
end of the charging process; follow the
correct acid level. There are correspon-
ding indicators on the battery.

ƽ

Danger

Danger of caustic material!
– Adding water to the battery in its dischar-

ged state can cause the acid to leak.

– Use safety glasses while handling batte-

ry acid and follow the safety instructions
to avoid personal injury or damage to
clothes.

– Should the acid spray on to the skin or

clothes, rinse immediately with lots of
water.

ṇ

Warning

Risk of damage!
– Use only distilled or desalinated water

(VDE 0510) for filling the battery.

– Do not add any substances (so-called

performance improving agents), this will
void the warranty.

ṇ

Warning

Only use maintenance-free batteries while
replacing batteries in package appliances.

Î

If the emergency stop button is pressed,
turn the key switch to position 0 and re-
lease the emergency stop button by
turning.

Î

Turn the main switch to "1".

ṇ

Warning!

Risk of damage. Raise the squeegee tool
before reversing.
Note
To put the brush drive out of operation im-
mediately release the control handle.

ṇ

Warning

Risk of damage. Only use the recommended
detergents. With respect to different deter-
gents the operator bears the increased risk
regarding the operational safety and danger
of accident. Only use detergents that are
free from solvents, hydrochloric acid and hy-
drofluoric acid.
Note
Do not use highly foaming detergents. Ob-
serve the meter mixing notes.

Detergent is added to the fresh water on the
way to the cleaning head with the help of a
dosaging device.

Note
1% detergent gets added via the metering
equipment. The metering can be set bet-
ween 0 and 3%. For higher metering, you
can add the entire quantity of detergent to
the fresh water tank.
The metering equipment has been designed
for 2.5 litre (0.66 gal) detergent bottles.

ṇ

Warning

Risk of blocking on account of drying deter-
gent. The flow meter of the metering equip-
ment can stick on account of drying
detergent and hamper the functioning of the

Maintenance-free batteries (wet batte-
ries)

Recommended batteries

Order No.

Description

6.654-093.0 75 Ah, maintenance-free, 2

pieces required

6.654-097.0 80 Ah, maintenance-free, 2

pieces required

Start up

Operation

Chemical filling

Advertising
This manual is related to the following products: