1.7.2 Dimensions
See Figure 1 (following page) for a diagram

showing the heater's exterior dimensions and dimen-
sions to critical connections on the heater.

SECTION 2.
Installation Instructions

WARNING

Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide
in flue gases which could result in severe injury,
or death. For indoor installations, as an
additional measure of safety, Waterpik
Technologies strongly recommends installation
of suitable Carbon Monoxide detectors in the
vicinity of this appliance and in any adjacent
occupied spaces.

AVERTISSEMENT

Une installation ou un entretien inadéquat peut
causer la nausée ou l’asphyxie en raison du
monoxyde de carbone présent dans les gaz de
combustion et même entraîner des blessures
graves ou la mort. Pour les installations
intérieures, comme mesure de sécurité
additionnelle, Waterpik Techonologies
recommande fortement l’installation de
détecteurs de monoxyde de carbone près de
cet appareil ainsi que dans les espaces
adjacents occupés.

2.1 Introduction

Install the Lite2 heaters, vent caps and

drafthoods in accordance with the procedures in this
manual, local codes and ordinances, and in accordance
with the latest edition of the appropriate national code

Table 1. Altitude Designations for the Lite2 Heater.

(see Section 1.4 "Codes and Standards").

All gas-fired products require correct installation

to assure safe operation. The requirements for pool
heaters include the following:
1.

Field assembly (if required)

2.

Appropriate site location (clearances) and
flooring

3.

Sufficient combustion and ventilation air

4.

Properly sized gas meter and piping

5.

Proper electrical wiring (if required)

6.

Adequate water flow

This manual provides the information needed to

meet these requirements. Review all application and
installation procedures completely before continuing
the installation.

2.2. Field Assembly

The Lite2 heater is shipped from the factory with

the top assembly in the low-profile configuration for
outdoor installation. The Lite2 heater is design certified
for indoor installation (U.S. only) when equipped with
a drafthood, which must be installed without modifica-
tion.

The Lite2 heater is also certified for installation in

an outdoor shelter in Canada when equipped with a
drafthood. An outdoor shelter is an enclosure not
normally occupied which does not communicate
directly with occupied areas.

Check the rating plate on the heater or the Parts

List (Section 11) of this manual for the correct Jandy
drafthood or vent cap part number. See instructions
supplied with the drafthood or vent cap for installation
and attachment. When the drafthood is used, locate
the heater so as to be in the same atmospheric pres-
sure zone as the combustion air inlet to the heater.

2.3 Location Requirements

2.3.1 Introduction

CAUTION

When pool equipment is located below the pool
surface, a leak from any component can cause
large scale water loss or flooding. Water Pik
Technologies cannot be responsible for such
water loss or flooding or resulting damage.

ATTENTION

Lorsque l’équipement d’une piscine est situé
sous la surface de l’eau, une fuite provenant de
n’importe quel élément peut causer une perte
d’eau importante ou une inondation. Water Pik
Technologies n’est pas responsable des pertes
d’eau, des inondations ou des avaries causées
par une installation ou un entretien inadéquat.

ALTITUDE

UNITED

CANADA

DESIGNATION

STATES

LOW ALTITUDE

0-3000 FT

0-2000 FT
(0-610 m)

MID ALTITUDE

3001-6000 FT

2001-4500 FT
(611-1370 m)

HIGH ALTITUDE

6001-10,000 FT

NOT
APPLICABLE

LP

LOW ALTITUDE

0-5000 FT

0-4500 FT
(0-1370 m)

HIGH ALTITUDE

5001-10,000 FT

NOT
APPLICABLE

NATURAL GAS