Waterpik Technologies LG User Manual

Page 7

Advertising
background image

Model LG Pool and Spa Heater

Page 5

Figure 1. General Configuration.

*

Ratings shown are for both natural and propane gas.

Venting Dimensions

Model

Heater

U.S. Indoor or

Firing Rate / Hr.*

Width

Vent

Outdoor

CAN Outdoor

(1,000's)

Diameter

Dim "H"

Shelter Dim "H"

in

(cm)

in

(cm)

in

(cm)

in

(cm)

BTU

(kcal)

LG125

15

(38)

5

(13)

17 3/8

(44)

16 1/4

(41)

125

(32)

LG175

18

(46)

6

(15)

18

(46)

24 1/8

(61)

175

(44)

LG250

22 1/2

(57)

7

(18)

18 1/4

(47)

25 1/4

(64)

250

(63)

LG325

26 3/4

(68)

8

(20)

18 7/8

(48)

26 1/2

(67)

325

(82)

LG400

31 3/4

(81)

9

(23)

21 1/2

(55)

27 1/2

(70)

400

(101)

The Lite2 LG heater may be installed indoors or

outdoors as outlined in later sections. Location of the
heater below or above the pool water level affects
operation of its water pressure switch. See sections
on water piping and heater start-up for more informa-
tion about this.

Avoid placing the heater in locations where it can

cause damage by water or condensate leakage. If this
is not possible, provide a suitable drain pan to catch
and divert any leakage. The pan must not block natural
flow of air around the heater.

All criteria given in the following sections reflect

minimum clearances as stated in the national stan-
dards. However, each installation must also be evalu-
ated taking into account the prevailing local conditions

such as wind speed and direction, proximity and
height of walls that may block ventilation or cause
down drafts, and proximity to public access areas.

2.3.2 Clearances
The heater must be placed to provide clearances

on all sides for maintenance and inspection. There
must also be minimum distances maintained from
combustible surfaces (see Table 2).

At least 20" (500mm) access must be available in

front of the heater for burner removal.

If the heater is to be installed in a garage, or

similar structure, all burners and burner ignition
devices must have a minimum 18" (457mm) clearance
above the floor.