PERIODIC CLEANING - Delime Internal Heating Tank


PRECAUTIONS:
Water in main tank is EXTREMELY HOT
(around

200ºF)

FREQUENCY:

Weekly


TOOLS:

Wells Deliming Solution Bottle (p/n 85377)

Plastic Scouring Pad

Clean Cloth or Sponge

Kay Orange Neutralizer and Delimer (Kay p/n 55905)



Begin with the HEATER SWITCH

ON

, MAIN TANK full and at

temperature (i.e. HEAT light not lit), and with SATELLITE full of hot
water.


Disconnect water to unit, or turn off main water supply valve.


Pour contents (1 oz.) of Neutralizer and Delimer packet into the plastic
solution bottle.


Fill the rest of the bottle with hot water from the satellite faucet.


Attach quick-disconnect fitting cap on bottle.


Invert the solution bottle over the quick-disconnect fitting on the
dispenser. Insert the bottle until it locks into place.

Squeeze solution bottle until all solution is forced into dispenser.


Press release on quick-disconnect. Remove solution bottle. Wipe clean
the quick-disconnect fittings. Rinse solution bottle with clean water.


Press TANK HEATER SWITCH to

OFF

[O]. Allow cleaning solution to

soak in main tank for 30 minutes.

CONTINUED ON PAGE 12

CLEANING INSTRUCTIONS (continued)

11

FIRST AID


EYES: In case of contact,
immediately flush with warm
water for 15 minutes.
Contact a physician if
irritation persists.


SKIN: Wash with soap and
water.
Contact a physician if
irritation persists.


INGESTION: If swallowed,
drink plenty of water and
contact a physician


KAY CHEMICAL CO.
EMERGENCY PHONE
(800) 304-0824


INGREDIENTS
Organic acids. Non-toxic
when used as directed.