Troubleshooting 23, 22 troubleshooting – Whistler PP150AC User Manual

Page 13

Advertising
background image

TROUBLESHOOTING

23

PROBLEM: Low Battery Alarm On All The Time

Problem

Solution

Input voltage below

Keep input voltage above

10.5 volts.

10.5 volts to maintain
regulation.

Poor or weak battery

Replace battery.

condition.
Inadequate power being

Check condition of

delivered to the inverter

cigarette lighter plug and

or excessive voltage drop.

socket. Clean or replace as
necessary.

Yellow LED on

Problem

Solution

Equipment has a high

Turn inverter power switch

start up surge.

OFF (O) and then ON (l)
again until the inverter
powers your appliance.
Repeat as necessary
to get your appliance
"started".

Battery voltage below

Recharge or replace

10 volts.

battery.

Equipment being operated

Use a higher capacity

draws too much power.

inverter or do not use this
equipment.

Inverter is too hot (thermal

Allow inverter to cool.

shutdown mode).

Check for adequate
ventilation. Reduce the
load on the inverter to
rated continuous power
output.

PROBLEM: TV Interference

Problem

Solution

Electrical interference from

Add a Ferrite data line filter

inverter.

on to the TV power cord.
This filter is available at
RadioShack,
part number 273-105.

PROBLEM: Low or No Output Voltage

Problem

Solution

Automotive system requires

Turn ignition key to

ignition to be on.

accessory position.

Inverter fuse blown.

Replace fuse according to
Guidelines in "Don’t Blow
A Fuse" Section of this
manual.
Make sure that inverter is
connected to power source
with correct polarity.

Using incorrect type of

Use true RMS reading

voltmeter to test output

meter.

voltage.

See "For You Technical
Types"
Section of this manual.

22

TROUBLESHOOTING

Advertising
This manual is related to the following products: