TIMING CHART:

5 Standard Factory Pre-Set Timing Modes.
Can be set to any customer requirement of 15.75-40Khz hor and 40-100Hz vert.

Timing shown is based on 801GC/GX signal generator


CGA

MID- RES Mode 3 Mode4 Mode 5

HORIZONTAL

640X240

773X384

640X480 720X400 800X600

VGA_M3 VGA_2 VG900602

Scan freq.

15.725kH 24.394kHz

31.469kHz 31.469Khz 37.879KHz

scan per.

63.594us

41.00us

31.777us 31.777us 26.00us

sync pulse

4.688us

3.00us 3.813us 3.813us 3.200us

front porch

2.187us

2.910us

0.636us 0.636us 1.000us

active vid.

50.00us

30.690us

25.422us 25.422us 20.000us

back porch

6.719us

4.440us

1.906us 1.906us 2.200us

sync polarity ( - ) ( - ) ( - ) ( - ) ( + )

VERTICAL

Vert. scan freq.

60.018Hz

57.534Hz

59.941Hz 70.087Hz 60.317Hz

scan per.

16.662ms

17.384m 16.683ms 14.268ms 16.579ms

sync pulse

0.191ms

0.164ms

0.064ms 0.064ms 0.106ms

front porch

0.190ms

0.451ms

0.318ms 0.318ms 0.02ms

active vid.

15.263ms

15.621ms

15.253ms 12.711ms 15.840ms

back porch

1.018ms

1.148ms

1.048ms 1.048ms 0.607ms

sync polarity ( - ) ( - ) ( - ) ( + ) ( + )