001 + - 048

14

If NO DMX signal is present, you will see the display (the first - changes
to a + ) as follows:

If an alert has been triggered with the presence of DMX signal, you will see
the display (the second - changes to a + ) as follows:

001 - + 048

If an alert has been triggered without the presence of DMX signal, the
display will look as follows:

001 + + 048

[ /Enter ]

Reset: This option allows you to reset all parameters to factory default.
This resets all parameters found in the setup menu, the display to read out
in %, and erases all Color Changer/Gobo Changer status information.

7. COMMANDS

This is the menu you use to send local commands to the Color Changers and
Gobo Changers.

Pressing [ - ] at any of the following options will bring up a question mark (?)
behind the option. Pressing [

+

] and [ - ] will increment and decrement

numbers or toggle options. Pressing [ /Enter ] will confirm your selection and
the question mark will go away.

[ - ]

DMX ALL - This will send commands to all Color Changers or Gobo
Changers connected to this Power Supply. Pressing [ /Enter ] allows you
to select the DMX channel of the individual Color Changer or Gobo
Changer which you wish to send commands to. Channels with Color
Changers or Gobo Changers set to them will be indicated by an asterisk.

[ - ]

Re-Init

-

This will cause the Color Changers or Gobo Changers to

re-calibrate their gelstrings or gobo carriers.

[ /Enter ]

Shutdown - This will shut down motor drive in the selected Color Changer
or Gobo Changer. The unit will not respond to position commands.

[ /Enter ]