Wolf Appliance Company CT15E User Manual
Page 14

14
W O L F
E L E C T R I C C O O K TO P S
E L E C T R I C A L
R E Q U I R E M E N T S
R E Q U I R E D P O W E R S U P P LY
Model CT15E
240 V AC / 60 Hz / 20 amp service
208 V AC / 60 Hz / 15 amp service
Models CT30E and CT30EU
240 V AC / 60 Hz / 40 amp service
208 V AC / 60 Hz / 40 amp service
Model CT30E-208/S
208 V AC / 60 Hz / 40 amp service
Models CT36E and CT36EU
240 V AC / 60 Hz / 50 amp service
208 V AC / 60 Hz / 40 amp service
M A X I M U M C O N N E C T E D L O A D
Model CT15E
3.7 kW at 240 V AC
2.8 kW at 208 V AC
Models CT30E and CT30EU
8.1 kW at 240 V AC
6.1 kW at 208 V AC
Model CT30E-208/S
7.9 kW at 208 V AC
Models CT36E and CT36EU
10.5 kW at 240 V AC
7.9 kW at 208 V AC
Verify that power is disconnected from
the electrical box before proceeding.
The Wolf electric cooktop requires a separate,
grounded 3-wire service with its own circuit
breaker. Locate the electrical supply within the
shaded area shown in the Installation Specifi-
cations illustration for your specific model on
pages 6–11.
This appliance must be installed in accordance
with National Electrical Codes, as well as all
state, municipal and local codes. The correct
voltage, frequency and amperage must be
supplied to the appliance from a dedicated,
grounded circuit which is protected by a
properly sized circuit breaker or time delay
fuse. The proper voltage, frequency and power
ratings are listed on the product rating plate,
located on the underside of the cooktop. Refer
to the illustration on page 3 for location of the
rating plate.