Wegener Communications 6420 User Manual

Page 122

Advertising
background image

iPump 6420 User’s Manual

www.wegener.com

800070-01 Rev B

Appendix 2, Page 118

MAX-ACCESS

read-only

STATUS mandatory

::= { tunerGroup 195 }

-- M_EBNO_AT_MARGIN_LVL

ebnoAtMarginLvl OBJECT-TYPE

SYNTAX INTEGER {

false(0)

true(1)

}

MAX-ACCESS

read-only

STATUS mandatory

::= { tunerGroup 199 }

-- M_CARRIER_STATUS

carrierStatus OBJECT-TYPE

SYNTAX INTEGER {

locked(0)

notLocked(1)

noSignal(2)

signalOverload(3)

}

MAX-ACCESS

read-only

STATUS mandatory

::= { tunerGroup 64 }

-- PCMI_GRP_SETTINGS (indexes: 1)

settingsGroupTable OBJECT-TYPE

SYNTAX SEQUENCE OF settingsGroupEntry

MAX-ACCESS

not-accessible

STATUS mandatory

::= { pcmiData 3 }

settingsGroupEntry OBJECT-TYPE

SYNTAX settingsGroupEntry

MAX-ACCESS

not-accessible

STATUS mandatory

INDEX { settingsGroupIndex }

::= { settingsGroupTable 1 }

settingsGroupEntry ::= SEQUENCE {

settingsGroupIndex INTEGER (0..65535) }

-- index 0 (main)

settingsGroupIndex OBJECT-TYPE

SYNTAX INTEGER {

commanded(1)

lastsuccess(253)

perm(254)

current(255)

temp(256)

}

Advertising