Normal Operating Pressures
NOTE: Values provided in chart are typical pressures. Indoor unit matchup, indoor air quality and indoor load will cause pressures to
vary.
Temperature of the Air
Entering the Outdoor Coil
Model
-24
-36
-48
-60
Liquid
Suction
Liquid
Suction
Liquid
Suction
Liquid
Suction
Cooling—1st Stage (Low Capacity)
65ºF
232
146
225
144
235
144
225
138
75ºF
264
148
261
147
268
145
264
141
85ºF
307
149
302
149
310
147
305
142
95ºF
353
151
349
151
356
148
352
146
105ºF
403
153
397
153
407
150
405
148
115ºF
460
155
461
157
466
152
459
150
Cooling—2nd Stage (High Capacity)
65ºF
240
143
239
139
244
140
241
134
75ºF
279
145
278
141
283
141
280
136
85ºF
322
147
322
143
326
144
324
137
95ºF
371
149
367
146
374
147
373
138
105ºF
423
151
426
148
427
148
425
142
115ºF
485
154
489
151
491
151
486
146
Heating—1st Stage (Low Capacity)
40ºF
337
93
328
98
369
75
351
63
50ºF
322
117
333
118
366
114
335
92
Heating—2nd Stage (High Capacity)
20º
279
62
296
62
311
58
308
59
30ºF
288
76
309
75
334
72
323
70
40ºF
302
93
322
92
354
89
318
69
50ºF
306
112
336
113
381
108
329
82