3.3 LED Indicators


Eight LED’s on the front of the modem indicate the following states:


Transmit Data 1

Green

On when modem 1 is transmitting data.

Receive Data1

Green

On when a RF carrier of greater than 0.9uV is detected

PSU 1

Red

On when Modem 1 power supply is good.

Fail 1

Red

On when a fault is detected in Modem 1


Data 2

Green

On when modem 2 is transmitting data.

Receive Data 2

Green

On when a RF carrier of greater than 0.9uV is detected

PSU 2

Red

On when Modem 2 power supply is good.

Fail 2

Red

On when a fault is detected in Modem 2


3.4 Fuses

Fuse 1

1 Amp Fuse for modem 1 PSU

Fuse 2

1 Amp Fuse for modem 1 PSU



3.5 Program Switch

Three way switch for changing the parameters of both modem 1 and modem 2.


Central

Run

Right

Program modem 1

Left

Program modem 2


3.6 Alarm Reset

Resets alarm states


3.7 Antenna Connections

Two 50 ohm, N-Type Sockets.


Antenna 1

Socket for Antenna 1

Antenna 2

Socket for Antenna 2


3.8 Power Supply

Three pin plug for 240V mains power supply is


4.0 OPERATION

When power is applied to the Dual Redundant Base Station all the monitored parameters are checked along
with the LED’s. If no faults are found modem 1 is enabled. The Duty Cycle Timer is enabled and this then cycles
the two modems according to the time set in the service menu. ( 1 to 48 Hours)

If a fault is detected in the operational modem then the Fault LED will light, the Fault Relay will energise, an
error code will be set in the service menu and the alternative modem will be selected.

A transmission is started by sending data to RD (pin 2) on the serial communication port. The operational radio
modem places this data in the transmitter buffer memory while it checks to see if the RF. channel is free. If it is