Western Telematic IPS-800-D20 User Manual

Page 14

Advertising
background image

3-4

IPS-800/1600-D20 Series - User’s Guide

iii. Via Modem: Use your communications program to dial the

number for the phone line which is connected to your external

modem. The Plug Status Screen should be displayed as shown

in Figure 3.2. Note that in order to communicate with the

unit via modem, you must first access the command mode via

Network or Local PC, and use the Serial Parameters Menu to

set the Port Mode to "Modem."

2. Test Switching Functions: You may wish to perform the following tests

in order to make certain that the IPS is responding to commands.
a) Reboot Outlet: If you are communicating with the unit via the Web

Browser Interface, select the button in the "Boot" column for Plug 1,

and then click on "Apply." If you are operating the unit via the Text

interface, type

/BOOT 1 and press [Enter]. The status indicator

for Plug 1 should go off, pause for a moment, and then go back on,

indicating that the boot cycle has been successfully completed.

b) Switch Outlet Off: From the Web Browser Interface, select the

button in the "Off" column for Plug 1, and then click "Apply." From

the Text Interface, type

/OFF 1 and press [Enter]. The status

indicator for Plug 1 should go Off, indicating that the command has

been successfully completed. Leave Plug 1 in the "Off" state, and

then proceed to the next step.

c) Switch Outlet On: From the Web Browser Interface, select the

button in the "On" column for Plug 1, and then click "Apply." From

the Text Interface, type

/ON 1 and press [Enter]. The status

indicator for Plug 1 should then go back On, indicating that the

command has been successfully completed.

3. Log Out: When you have finished communicating with the unit it is

important to always log off by issuing the appropriate IPS command,

rather than simply closing your Telnet or communications program.

When you log off using the proper IPS command, this ensures that the

unit has completely exited from command mode, and is not waiting for

the inactivity timeout to elapse before allowing additional connections.
a) Web Browser Interface: Click on the "Log Out" button.
b) Text Interface: Type

/X and press [Enter].

This completes the Quick Start Guide for the IPS. Prior to placing the unit into

operation, it is recommended to refer to the remainder of this User’s Guide for

important information regarding advanced configuration capabilities and more

detailed operation instructions. If you have further questions regarding the IPS

unit, please contact WTI Customer Support as described in Appendix C.

Advertising
This manual is related to the following products: