Dip switch feature selection, Configuration options – Welch Allyn SCANTEAM 6980 User Manual

Page 13

Advertising
background image

8

SCANTEAM 6980 User’s Guide

Dip Switch Feature Selection

Parameter

RSĆ232 Type

Data Bit and

Parity

Setting

SW 1

Configurations

8 Bit None

ON*

SS, ES Code

Setting

SW 3

Enabled

OFF*

Disabled

ON

RSĆ232 Type

Baud Rate

Setting

SW 4

Check Sum

Setting

SW 6

Disabled

OFF*

Enabled

ON

STX, ETX, DLE

Setting

SW 7

Enabled

ON*

Disabled

OFF

Mode

Setting

SW 8

Normal Operating

ON*

Programming

OFF

SW 5

SW 2

ON*

OFF

ON

OFF

Reserved

OFF

7 Bit Even

ON

7 Bit Odd

OFF

1200

ON

ON

OFF*

ON

OFF

2400

OFF

9600

ON*

19200

OFF

Notes:

Asterisk (*) Indicates Factory Default Setting.

Data Format includes one Start Bit and one Stop Bit.

Configuration Options:

Program Mode Download Controlled

The SCANTEAM 6980 Magnetic Stripe Reader has two
operating modes: Normal Operation and Programming.

In Normal Operation mode, everything typed on a connected
keyboard is passed to the host PC directly. A program utility is

required for Programming mode. The utility will monitor the
keys pressed and program the MSR via the RSĆ232 port. The

green LED will flash and the MSR will beep as each command
key is typed during programming.

Advertising