Welch Allyn SCANTEAM 6980 User Manual

Page 9

Advertising
background image

4

SCANTEAM 6980 User’s Guide

Installation

All versions of the SCANTEAM 6980 depend on an external
source of +5 VDC power to operate. Since most RSĆ232

interface ports don't provide a power source, an external + 5
VDC power supply must be plugged into the molded receptacle

in the SCANTEAM 6980's interface connector for all versions,
except the 6980-5 [.
The SCANTEAM 6980 is easily installed into a PC system in the
following steps:
1) Turn the system power off.

2) Connect the MSR cable to the PC's 9 pin D male RSĆ232

port.

3) Connect the 5 VDC adaptor cable to the MSR and then plug

the 5 VDC adaptor into a 120 vac receptacle.

4) The MSR can be mounted to the wall, the side of a PC, a

keyboard, or simply to a counter with the hook and loop

fastener strips included with the product. Alternatively, the
screws holding the bottom plastic case on the MSR may be

replaced with longer screws for mounting purposes.

5) Turn the system power on.

6) Configure your host device to accept RSĆ232 data on its

RSĆ232 port.

7) Test the SCANTEAM 6980's host interface configuration by

passing a magnetic stripe card through the SCANTEAM
6980. The magnetic stripe data should appear on your PC

screen. If the data does not appear on the screen, you may
have to modify the output data configuration of the

SCANTEAM 6980 (see page 6, Configuration Options).

[

The SCANTEAM 6980–5 will only operate when the host device supplies
power on pin 9 of its DB-9 RS-232 interface port.