Fixture setup and configuration – Wybron Transition Optic User Manual

Page 10

Advertising
background image

10

Fixture Setup and Configuration

Installing the Lamp

DANGER: Disconnect fixture from line voltage before replacing

lamp.

CAUTION: Lamp and lamp mounting surfaces are hot! Allow lamp to

cool 10 minutes before replacing

Lamp Specifications

Lamp socket / base: G22

Part#
UHI-S150DW/A/UVP

Lamp, Eurospot UHI Series 3000K 150W

UHI-S150DM/A/UVP

Lamp, Eurospot UHI Series 4200K 150W

CDM150/T6/830

Lamp, CDM 150W with UV Fade Block

3000K

CDM150/T6/942

Lamp, CDM 150W with UV Fade Block 4200K

Figure 1.1

Disconnect fixture from AC power.

Remove lamp plate by unscrewing mounting screws and pulling the

lamp assembly straight back from the illuminator.

Grasping lamp by the base remove old lamp from the socket.

Insert new lamp into base. Lamp is fully seated when spring clips snap

over lamp base.

CAUTION: Touching the glass lamp envelope can reduce lamp life.

Handle new lamps with a clean cloth. Fingerprints can
be cleaned off the lamp envelope with alcohol and a
clean cloth.

Locating the Fixture

The Transition CMY fiber illuminator is designed to be surface mounted,
located in a cabinet or closet, or hung from mounting pipe with the optional
pipe bracket.

Surface Mounting

The Transition may be surface mounted on a hard surface table,
counter top, or floor (wood, laminate, metal, tile).
Do not mount the Transition on soft surfaces such as carpet, linoleum,
cushions, or fabric.