Transition Quick Start Configuration

1. Connect the Equipment

a) Connect fiber bundle common end to the Transition output port.
b) Connect the Transition to a DMX source with a 5-pin cable
c) Connect to AC power (110 – 240 VAC 50/60Hz)

2. Control Transition with DMX

Leave Transition addressed at channel 1 (factory default)
DMX channel 1 controls Cyan (0% = no color, 100% = full saturation)
DMX channel 2 controls Magenta (0% = no color, 100% = full
saturation)

DMX channel 3 controls Yellow (0% = no color, 100% = full saturation)
DMX channel 4 controls Dimmer (0% = no output, 100% = full output)
DMX channel 5 controls Twinkle wheel (Transition TW model
only)

3. Control Transition using Demo Mode

a) Press ‘Menu’ until display reads ‘dEn
b) Press ‘Enter’, display will read ‘OFF’
c) Press ‘+’ or ‘-‘ to scroll through demo mode options
d) Press ‘Enter’ at the desired demo mode. Transition will

immediately begin executing the demo loop.