Specifications, Ordering information, Watlow sales offices – Watlow Electric Series 94 User Manual

Page 2: Information, Ordering

Advertising
background image

Ordering

Information

9 4 - 1 - 0 0

Series 94
Microprocessor-based

1

16

DIN, single input, dual output

4-digit displays

NEMA 4X (IP65)

b

Option

A = Without NEMA 4X (IP65) Rating
B = With NEMA 4X (IP65) Rating
CE Option
A = Non CE Compliant
B = CE Compliant
Output 1 (Limit)
D = Electromechanical relay, Form C, 5A,

without contact suppression

ac

Output 2 (Alarm)
A = None
C = Switched dc output, non-isolated
D = Electromechanical relay, Form C, 5A,

without contact suppression

ac

K = Solid state relay, Form A, 0.5A, without

contact suppression

c

Line Voltage/Power
0 =

100-240V~ (high voltage)

1 =

12-24V

ı

(ac/dc)

(low voltage)

Display

Upper/Lower

RR = Red/Red
RG = Red/Green
GR = Green/Red
GG = Green/Green

a

Electromechanical relays are not recommended for PID
control. They are warranted only for 100,000 contact closures.

b

To effect NEMA 4X (IP65) rating requires a minimum
mounting panel thickness of 0.06 inch (1.5 mm) and surface
finish not rougher than 0.000032 inch (0.000812 mm).

c

Switching inductive loads (relay coils, etc.) requires using an
RC suppressor.

Specifications

Control Mode
• Microprocessor-based
• Single input, dual output
• Limit and alarm
Agency Approval
• FM approved, Class 3545, File J.I. 0D5A1.AF
Operator Interface
• Sealed membrane front panel
• Dual, 4-digit red or green displays
• Advance, Increment, Decrement, and Reset keys
Accuracy
• Calibration accuracy and sensor conformity: ±0.1% of span,

±1°C @ 77°F ± 5°F/25°C ± 3°C ambient and rated line
voltage

• Accuracy span: 1000°F/540°C minimum
• Temperature stability: ±0.2°F/°F or ±0.1°C/°C rise in

ambient maximum

• Voltage stability: ±0.01% of span per percent of rated line voltage
Sensors/Inputs
• Thermocouple, grounded or ungrounded sensors
• RTD 2- or 3-wire, platinum, 100

@ 0°C calibration to DIN

curve (0.00385

/

/°C) or JIS curve (0.003916

/

/°C); user

selectable

• Sensor break protection de-energizes limit output to

protect system

• °F or °C display, user selectable
Input Range
Specified temperature ranges represent the controller’s

operational span.

• Thermocouple

Type B

32

to 3308°F

or

0

to 1820°C

Type J

32

to 1382°F

or

0

to

750°C

Type K

-328

to 2282°F

or

-200

to 1250°C

Type N

32

to

2282°F

or

0

to 1250°C

Type S

32

to 2642°F

or

0

to 1450°C

Type T

-328

to

662°F

or

-200

to

350°C

• RTD Resolution (DIN or JIS)

-328

to 1292°F

or

-200

to

700˚C

0.1°

-199.9

to 999.9°F

or -199.9

to 700.0˚C

Output 1 Limit
• Electromechanical relay
Output 2 Alarm
• Electromechanical relay
• Switched dc
• Solid state relay
Output Specifications
• Electromechanical relay

c

, Form C, 5A @ 120/240V~

or 30V

Î

(dc) maximum, rated resistive load, without contact

suppression.

• Switched dc signal provides a non-isolated minimum turn on

voltage of 3V

Î

(dc) into a minimum 500

load,

maximum on voltage not greater than 12V

Î

(dc) into an

infinite load.

• Solid state relay

c

, Form A, 0.5A @ 24V~ min. to

265V~ max. Opto-isolated, without contact
suppression. Off state output impedance is 31M

.

Output Configurations
Output 1 selections: Limit Control
• Limit output
Output 2 selections:
• Process with flashing alarm message
• Process without alarm message
• Alarm with separate high and low set points
• Hysteresis: 1 to 9999°C/°F

Line Voltage/Power

• 100-240V~ (85-264V~); 50/60Hz ±5%
• 12-24V

ı

(ac/dc) (10-26

ı

[ac/dc]); 50/60Hz ±5%

• Power consumption 7VA (12 to 24V

ı

[ac/dc])

12VA (100-240V~)

• Data retention upon power failure via non-volatile memory
Operating Environment
• 32 to 149°F/0 to 65°C at 115V~ line voltage power
• 32 to 140°F/0 to 60°C at 230V~ line voltage power
• 0 to 90% RH, non-condensing
• Storage temperature: -40° to 185°F/-40° to 70°C
Terminals
• Size 6 universal head screw terminals accepts 20-14 gauge wire
Dimensions
Height

2.1"

53 mm

Width

2.1"

53 mm

Overall Depth

4.7"

119 mm

Behind panel depth

4.1"

104 mm

Weight

0.5 lb

0.2 kg

United States Sales Offices:

Atlanta/Greenville, (770)908-9164 • Austin, (512)249-1900 • Charlotte/Columbia, (704)541-3896 •

Chicago, (847)458-1500 • Cincinnati, (513)398-5500 • Cleveland, (330)467-1423 • Dallas, (972)422-4988 • Denver, (303)798-7778 •
Detroit, (248)651-0500 • Houston, (281)355-6015 • Indianapolis, (317)575-8932 • Kansas City, (913)897-3973 • Los Angeles, (714)935-2999 •
Maryland/Virginia, (410)840-8034 • Minneapolis, (612)431-5700 • Nashville, (615)264-6148 • New England, (603)882-1330 •
New York/New Jersey/Philadelphia, (215)345-8130 • New York, Upstate, (716)438-0454 • Orlando, (407)351-0737 • Phoenix, (602)708-1995 •
Pittsburgh, (412)323-0548 • Portland, (503)245-9037 • St. Louis, (314)878-4600 • Sacramento, (707)425-1155 • San Diego, (760)728-9188 •
San Francisco, (408)980-9355 • Seattle, (425)222-4090 • Tampa/St. Petersburg, (813)926-3600 • Tulsa, (918)496-2826 •
Winston Salem/Raleigh, (336)766-9659 • Wisconsin, (414)723-5990

Asian Sales Offices:

Australia, +61 (3) 9335-6449 • China, +86 (21) 6229-8917 • Japan, +81 (03) 5403-4688 • Korea, +82 (02) 563-5777 •

Singapore, +65 777-5488 • Taiwan, +886 (0) 7-261-8397

European Sales Offices:

France, +33 (01) 3073-2425 • Germany, +49 (0) 7253-9400-0 •

Italy, +39 (02) 458-8841 • United Kingdom, +44 (0) 115-964-0777

Latin American Sales Office:

Mexico, +52 (42) 17-6235

For other product information, call Watlow’s FAX REPLY:

United States +1 (800) 367-0430 • Outside the United States +1 (732) 885-6344