Shut-down instructions, Start-up instructions – White Outdoor FUEL HD120 User Manual

Page 14

Advertising
background image

ON

OFF

For initial start-up after heater installation, follow steps 1-6.

For normal start-up, simply set the thermostat above room

temperature.

1. Connect electrical cord to an approved electrical

outlet.

2. Set thermostat to desired room temperature.

3. This heater has a manually operated toggle style

selector switch located on the top of the control box.

(Open the fan motor access panel to view) This

switch allows you to either heat or ventilate (no heat).

See Fig. 6 for selector switch positions.

FIG. 6

A. H

Heating

a. Open all manual fuel supply valves. Check for gas

leaks using an approved leak detector. The gas

control valve on the heater has a manual shut-off

feature incorporated into the valve assembly. Make

sure the indicator on the valve is turned to the on

position. See Fig 7.

b. When the selector switch is positioned to heat, the

red light on the ignition control will be on. At this

point, the motor will start, the igniter will spark and

ignition will occur. The heater will cycle based upon

interconnected control system.

FIG. 7

B. VVentilation

When the selector switch is positioned to vent, the

red light will NOT be on. The fan motor will start, but

the igniter will not spark, nor will ignition occur. This

feature is used typically when heat is not needed, but

air circulation is required. To discontinue the

ventilation feature, position the switch to off or heat,

or use the interconnected contacts (customer

supplied) to accomplish this task.

C. O

Off

Position the switch to midpoint.

ATTENTION

It is normal for air to be trapped in gas hose on new

installations. The heater may attempt more than one

trial for ignition before air is finally purged from line and

ignition takes place.

4. The direct spark ignition (DSI) control board within

this heater is self-diagnostic. The board works in

conjunction with a light emitting diode (L.E.D.) built

into the selector switch. The L.E.D. will flash a

specific continuous flash pattern depending on a

problem that occurs. Match the specific flash pattern

given by L.E.D. to the troubleshooting label applied to

inside of burner cap access panel of the heater. The

troubleshooting label identifies the causes of the

problem as it relates to specific flash pattern and

remedies to correct the problem. See also

Troubleshooting Data within this Owner’s Manual.

5. The gas control valve in this heater is a two stage

control. When a call for heat occurs, the valve will

open to its first stage rate. Depending upon

temperature requirements and temperature control

setting, the valve will then either remain at first stage

heat rate before the temperature control is satisfied,

or the valve will open completely to its second stage

capacity. If the valve opens to its second stage

capacity, it is designed to revert back to its first stage

heat rate before controller shuts the heater down.

6. Do not exceed input rating stamped on nameplate or

manufacturer’s recommended burner orifice

pressure for size orifice(s) used. Make certain that

the primary air supply to main burner is open and

free of dust, dirt and debris for complete, proper

combustion.

If the heater is to be shut down for cleaning, maintenance or

repair, follow steps 1 - 5. Otherwise, simply turn thermostat

to “off” or “no heat” for standard shut down.

1. Close all manual fuel supply valves.

2. With the heater lit, allow heater to burn off excess

fuel in gas supply hose.

3. Turn the indicator on the gas control to “off”.

4. Turn thermostat to “off” or “no heat” position.

5. Disconnect the heater from the electrical supply.

Shut-Down Instructions

HEAT
(UP)

OFF
(MID)

VENT
(DOWN)

Start-Up Instructions

13

Advertising