Alarm codes – WhisperKool EXTREME 5000TIR User Manual

Page 31

Advertising
background image

Page 31

CPSM

Mode

(Cont.)

CCT - Cellar Pre-Chill Duration: This parameter is set to 6 hours, but can be changed between

0-23.5 hours.

Con/Cof – Compressor On time (Con) and Off time (Cof) with a Probe 1 failure/Alarm. These

parameters are set at Con 40 min/Cof 10 min. In the event that there is a Probe 1 failure/Alarm,

the compressor/refrigeration system automatically starts a predetermined ON/OFF cycle, which

is controlled by the Con and the Cof parameters. The customer can adjust these parameters to

maintain the desired Bottle temperature.

Alarm Codes

Message

Cause

Solution

“P1”

Bottle Probe is Unplugged

Attach Bottle Probe to Unit

Faulty Bottle Probe Connection

1. Check Bottle Probe attachment at circular connector

2. Check Bottle Probe connection at green terminal block on

back of controller

Defective Bottle Probe

Replace the Bottle Probe

“P2”

Faulty Evaporator Probe

Connection

Check Evaporator Probe connection at green terminal block on

back of controller

Defective Evaporator Probe

Replace the Evaporator Probe

“HA”

Defective Bottle Probe

Replace the Bottle Probe

“LA”

The Bottle Probe is sensing a

temperature of 4° below the set

point

Allow the room to warm up which will increase the temperature

of the wine

Defective Bottle Probe

Replace the Bottle Probe

“POF”

The keypad is locked

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,

“PON” should appear