Caution, Operation, Ventilator warning light panel – Wells WVAE-30F User Manual

Page 13

Advertising
background image

NOTE: Fryer must be operated in accordance with the instructions in
the accompanying FRYER OPERATION MANUAL.

During normal operation, VENTILATOR POWER ON light will be the
only light illuminated on VENTILATOR WARNING LIGHT PANEL.

If the CHECK FILTERS light illuminates, check both GREASE BAFFLE
and the HEPA AIR FILTER for proper installation.

If REPLACE FILTERS light illuminates, replace both HEPA AIR
FILTER and CHARCOAL FILTER. Always replace both filters at the
same time.

NOTE: REPLACE FILTERS light is a warning that filters are nearing the
end of their service life. The fryer will continue to operate for a period of
time after REPLACE FILTER LIGHT turns ON to allow continued fryer
operation through a peak period. However, filters must be replaced
within a short time period or they will clog, disabling the fryer.

If SERVICE REQUIRED light illuminates, filters are restricted to the point
of insufficient airflow for proper operation. Fryer is shut down until the
underlying clogged filter situation has been corrected. Normally,
replacing both HEPA AIR FILTER and CHARCOAL FILTER will remedy
the condition. Reset the unit by turning FRYER POWER SWITCH to
OFF, then back to FRYER.

A failure of incoming electric power will cause a shut down of the unit.
Reset the unit by turning the FRYER POWER SWITCH to OFF, then
back to FRYER.

CAUTION:

HOT SURFACE

Exposed surfaces can be hot
to the touch and may cause
burns.

CAUTION:

SHOCK HAZARD

DO NOT splash or pour water
or grease onto control panel
or wiring.

IMPORTANT:
The fryer is disabled when
REPLACE FILTERS light is
illuminated. Note that the
fryer cannot operate if the
HEPA air filter is removed.

It is the responsibility of
the store management to
maintain sufficient spares
of HEPA air filters to avoid
prolonged shutdown of the
fryer when this filter is
expended.

Charcoal and HEPA air filters
cannot be cleaned.

Wells Manufacturing
assumes no liability for loss of
business due to filter related
shutdown.

OPERATION

11

VENTILATOR
POWER ON

VENTILATOR
POWER ON

CHECK

FILTERS

CHECK

FILTERS

REPLACE

FILTERS

REPLACE

FILTERS

SERVICE

REQUIRED

SERVICE

REQUIRED

VENTILATOR WARNING LIGHT PANEL

M3

8

1

301603

O

p

M

(

S

up

p

lem

en

ta

l)

N

F

P

A

H

o

o

d

Advertising
This manual is related to the following products: