Wagner HIGH PERFORMANCE AIRLESS SPRAYER User Manual

Page 13

Advertising
background image

© 1995 Wagner Spray Tech

13

All rights reserved.

them into a container of water or appropriate solvent
for the type of material with which you are painting.

11. Place the attached suction tube and return tube into

a container of water or appropriate solvent for the
type of material with which you are painting.

12. Increase the pressure to 1/2 the maximum pressure.

Let the water or solvent circulate for 2-3 minutes to
flush paint out of the pump, the suction tube and the
return tube.

Clearing the paint hose

1. To save paint left in the hose, release the gun safety

switch and carefully trigger the gun with the spray tip
removed against the inside of the paint container.

2. Turn the pressure control knob counterclockwise to

the minimum pressure setting.

3. Turn the PRIME/SPRAY knob to SPRAY (

).

4. Turn the pressure control knob slowly until paint

starts to flow into the bucket. As soon as the water
or solvent starts to come into the bucket, release the
trigger.

5. Change to clean water or solvent and continue

circulating for another 5 minutes to thoroughly clean
the hose, pump and spray gun.

6. Turn the pressure control knob counterclockwise to

its lowest setting.

7. Turn the PRIME/SPRAY knob to PRIME ( ).

8. Trigger the gun to remove any pressure which may

still be in the hose.

9. Lock the gun by turning the gun safety switch so

that it is parallel to the gun body.

10. Turn the motor switch to OFF.

Clearing the gun

1. Remove the spray gun from paint hose using two

adjustable wrenches.

2. Remove the filter housing from the gun. Place the

gun and the filter assembly into a container of water
or solvent to soak.

3. Cover the paint container and set it aside.

4. Clean the spray tip and gun filter with a soft brush.

Assemble the spray tip in the cleaning position with
the arrow pointing to the back of the gun.

5. Attach the paint hose to the gun and tighten using

two adjustable wrenches.

6. Turn the motor switch to ON.

7. Unlock gun trigger by turning the gun safety switch

so that it is parallel to the gun handle.

8. Turn the PRIME/SPRAY knob to SPRAY (

) and

point the gun to the side of the cleaning bucket.

9. Trigger the gun and gradually turn the pressure

control knob clockwise to 1/2 pressure. Continue to
trigger the gun for approximately 30 seconds.

10. Turn the pressure control knob counterclockwise to

its lowest setting.

11. Turn the PRIME/SPRAY knob to PRIME ( ).

12. Trigger the gun to remove any pressure which may

still be in the hose.

13. Lock the gun by turning the gun safety switch so

Advertising