11.6 PSTN Call Setup Signaling

Dual-Tone MultiFrequency (DTMF) signaling uses pairs of frequencies (one lower frequency
and one higher frequency) to set up calls. It is also known as Touch Tone®. Each of the keys
on a DTMF telephone corresponds to a different pair of frequencies.

Pulse dialing sends a series of clicks to the local phone office in order to dial numbers.

1

11.7 MWI (Message Waiting Indication)

Enable Message Waiting Indication (MWI) enables your phone to give you a message–
waiting (beeping) dial tone when you have a voice message(s). Your VoIP service provider
must have a messaging system that sends message waiting status SIP packets as defined in
RFC 3842.

11.8 Custom Tones (IVR)

IVR (Interactive Voice Response) is a feature that allows you to use your telephone to interact
with the ZyXEL Device. The ZyXEL Device allows you to record custom tones for the Caller
Ringing Tone
and On Hold Tone functions. The same recordings apply to both the caller
ringing and on hold tones.

11.8.0.1 Recording Custom Tones

Use the following steps if you would like to create new tones or change your tones:

1 Pick up the phone and press “****” on your phone’s keypad and wait for the message

that says you are in the configuration menu.

2 Press a number from 1101~1108 on your phone followed by the “#” key.

3 Play your desired music or voice recording into the receiver’s mouthpiece. Press the “#”

key.

1.

The ZyXEL Device does not support pulse dialing at the time of writing.

Table 54 Custom Tones Details

LABEL

DESCRIPTION

Total Time for All Tones

120 seconds for all custom tones combined

Time per Individual Tone

20 seconds

Total Number of Tones

Recordable

Ten
You can record up to ten different custom tones but the total time must

be 120 seconds or less.
For example you could record up to ten 12-second tones or up to six 20-

second tones.