York AY012MA321 User Manual

Page 5

Advertising
background image

246814-YTG-D-0606

Unitary Products Group

5

1. G4FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.

COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL MODEL

1

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

1 PH 13 SEER AC WITH MV - VARIABLE SPEED

AY018MA321

MV12B

5,8,10

17

FC/MC18B

600

18.4

12.8

14.50

12.00

MV12B

5,8,10

17

G4FD024H17T2A

600

18.4

12.8

14.50

12.00

AY024MA321

MV12B

5,8,10

17

FC/MC24B

800

24.0

17.7

14.50

12.00

MV12B

5,8,10

17

FC/MC30B

800

24.0

17.7

14.50

12.00

MV12B

5,8,10

17

FC/MC36B

800

24.0

17.7

14.50

12.00

MV12B

5,8,10

17

G4FD030H17T2A

800

24.0

17.7

14.50

12.00

MV12B

5,8,10

17

G4FD036H17T2A

800

24.0

17.7

14.50

12.00

MV16C

5,8,10,15,18,20

21

FC/MC36C

800

24.0

17.7

14.50

12.00

AY030MA321

MV12B

5,8,10

17

FC/MC36B

1000

29.2

21.4

11.70

10.40

MV12B

5,8,10

17

FC/MC42B

1000

29.4

21.6

12.00

10.40

MV12B

5,8,10

17

G4FD036H17T2A

1000

29.2

21.4

11.70

10.40

MV12B

5,8,10

17

G4FD046H17T2A

1000

29.4

21.6

12.00

10.40

MV16C

5,8,10,15,18,20

21

FC/MC36C

1000

29.4

21.6

11.70

10.40

MV16C

5,8,10,15,18,20

21

FC/MC42C

1000

29.4

21.6

11.70

10.40

MV16C

5,8,10,15,18,20

21

G4FD036H21T2A

1000

29.4

21.6

11.70

10.40

MV16C

5,8,10,15,18,20

21

G4FD042H21T2A

1000

29.4

21.6

11.70

10.40

AY036MA321

MV12B

5,8,10

17

FC/MC42B

1200

35.8

25.9

13.75

11.00

MV12B

5,8,10

17

G4FD046H17T2A

1200

35.8

25.9

13.75

11.00

MV16C

5,8,10,15,18,20

21

FC/MC42C

1200

36.0

26.1

14.00

11.50

MV16C

5,8,10,15,18,20

21

FC/MC48C

1200

36.0

26.1

14.00

11.50

MV16C

5,8,10,15,18,20

21

G4FD042H21T2A

1200

36.0

26.1

14.00

11.50

MV16C

5,8,10,15,18,20

21

G4FD048H21T2A

1200

36.0

26.1

14.00

11.50

MV20D

8,10,15,18,20,25

24

FC/MC48D

1200

36.0

26.1

14.00

11.50

MV20D

8,10,15,18,20,25

24

G4FD048H24T2A

1200

36.0

26.1

14.00

11.50

1 PH 13 SEER AC WITH AHP

AY012MA321

AHP18

2,5,8

17

—

430

15.5

9.9

13.50

11.00

AY018MA321

AHP18

2,5,8

17

—

650

18.0

12.4

13.00

11.00

AHP24

2,5,8,10

17

—

655

18.0

12.4

13.00

11.00

AY024MA321

AHP24

2,5,8,10

17

—

830

23.4

17.1

13.00

11.00

AY030MA321

AHP36

5,8,10,15,18

17

—

1040

28.8

21.0

10.90

9.90

AY036MA321

AHP42

5,8,10,15,18

21

—

1255

35.4

25.5

13.00

11.00

1 PH 13 SEER AC WITH F4FP

AY018MA321

F4FP024H06T2A

5,8,10

17

—

600

18.0

12.4

13.00

11.00

AY024MA321

F4FP030H06T2A

5,8,10,15

17

—

800

23.4

17.1

13.00

11.00

AY036MA321

F4FP042H06T2A

5,8,10,15

24

—

1200

35.4

25.5

13.00

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80ºF entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95ºF outdoor ambient divided by the total electric power in watt-hours at those conditions

.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BUT’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.