Xantrex Technology PROsine 2.0 User Manual

Page 30

Advertising
background image

Introduction

1–10

445-0089-01-01

Adjustable From the Configure Battery Menu

NOTE
Settings below are for Battery Type = Generic Gel.

Battery Size

200Ah

**

Default Battery Temperature

Warm

Battery Type

Generic Gel

**

Battery Temp. Coefficient

–27mV/°C

Bulk Mode Settings:
•

Max Voltage

•

Max Current (%C)

•

Threshold Voltage

•

Threshold Timeout

•

14.2V

•

25%

•

13.8V

•

3min

Absorption Mode Settings:
•

Max Voltage

•

Max Current (%C)

•

Max Timeout

•

Threshold Current (%C)

•

Threshold Timeout

•

14.2V

•

25%

•

8hr

•

1%

•

3min

Overcharge Mode Settings:
•

Max Voltage

•

Max Current (%C)

•

Max Timeout

•

14.2V

•

20%

•

0

Float Mode Settings:
•

Max Voltage

•

Max Current (%C)

•

Max Timeout

•

Threshold Voltage

•

Threshold Timeout

•

13.8V

•

200%

•

21days

•

12.5V

•

15min

Equalize Mode Settings:
•

Max Voltage

•

Max Current (%C)

•

Max Timeout

•

Threshold Voltage

•

Threshold Timeout

•

13.8V

•

200%

•

0

•

0

•

0

Constant Mode Settings:
•

Voltage Setpoint

•

Current Setpoint

•

13.5V

•

100A

Charger Mode

Standalone

Charger Type

3-Step

Charger High Battery V
Warning Offset

1.0V

NOTE
The values opposite the gray bar are set when you select a battery type. If you did
not subsequently change these settings, they do not need to be recorded.

Table 1-1 PROsine Default Values

Item

Default Value

Your Settings