Maintenance / specifications – XtremeMac XGC-1 User Manual

Page 11

Advertising
background image

MAINTENANCE / SPECIFICATIONS


PRECAUTIONS

1) Please take care in the handling of this precision device. If the unit is dropped or subjected to extreme shock, the

calibration may be thrown off. Calibration problems due to abuse, or droppage may affect the warranty.

2) DO

NOT expose the XGC-1 to water. It utilizes a ventilated enclosure to properly “sample” the CO

2

.




SPECIFICATIONS:

System operating voltage

120vac +/- 20% @ 50-60 Hertz

Maximum Switching amperage

15-amps @ 120vac

Overload protection

15-amp normal blow fuse

Operating temperature

30-120º F

Maximum humidity

95% RH (Non-condensing)

Temperature control range

50-115º F with a 7º F differential, +/- 3.6º

Humidity control range

20 - 80% RH with a 5% differential

Adjustable timer repeatability

+/- .5% under fixed conditions

Timer setting accuracy

+/- 10%

Hydro “ON” timer

30 seconds to 20 minutes

Hydro “OFF” timer

12 minutes to 480 minutes

24-hour timeclock accuracy

+/- 3% monthly

CO

2

Operating principle

Fuzzy Logic

, w / Single-beam Non-Dispersive Infrared (NDIR)

CO

2

Measurement range

0 – 5000 PPM CO

2

CO

2

Warm-up time

Minimum 10 minutes (full accuracy)

CO

2

Maximum drift per year

+/- 15 PPM

CO

2

Accuracy @ 77’F

+/- 5% of reading

CO

2

Repeatability

< 1% of Fixed Scale

CO

2

Calibration interval

Three years

CO

2

sensor Operating life expectancy

15 years typical

Dimensions

10” X 8” X 7”

Weight

Less than 6 lbs.

Relay operations

Minimum 100,000 electrical / 10,000,000 mechanical



MAINTENANCE:

1) Consult the troubleshooting chart for a listing of the most common problems.

2) DO NOT open the enclosure!!! There are no components that require maintenance.

3) Do not use this equipment for purposes other than what it is designed for. It will provide many years of trouble-free

service when used properly.


4) In the event you cannot solve the problem, first consult the dealer who sold the unit then contact the factory for

instructions on how to return it to the factory for repair.



PUBLISHED BY R & M Supply INC.

COPYRIGHT 2002 BY R & M Supply

ALL RIGHTS RESERVED.

Liability statement:
R & M Supply and their retailers and distributors are not responsible for any damage or injuries (consequential or otherwise)
arising from the use of this device. The purchaser assumes all responsibility for the use and proper installation of this device.

Page 11