BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL

POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

3.5

1.2

NOMINAL FLOW

RATE m

3

/h

0.286

0.062

0.190

0.043

0.095

0.031

0.333 0.114

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

136 Adjust.

NOMINAL THERMAL

POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

3.2

1.2

NOMINAL FLOW

RATE g/h

202

47

144

32

72

24

231

86

NOZZLE REFERENCE

86

40

71

32

50

28

88

56

OVERALL DIMENSIONS

Width:

860 mm.

Depth:

510 mm.

CUT OUT DIMENSIONS

Width:

830 mm.

Depth:

480 mm.

SUPPLY CONNECTIONS
Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non

rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark
Spark Generator

Ispra Control's BF 50066

230- 240V 0.6 YA T 120

Spark Gap

Fixed

Rear Left Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

Heat Input

1.0 kW (3412 BTU/HR)

Rear Right Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner (rapid)

Heat Input

3.0 kW (10236 BTU/HR)

Central Burner (Ultra-rapid Double-crown)

Heat Input

3.5 kW (11942 BTU/HR)

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid32
Rapid40
Ultra-rapid56
Aeration adjustment none

NATURAL

GAS

20

mbar

TYPE

OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37

mbar

1/100 mm

1/100 mm

VALUE

=

49.92

MJ/Kg

VALUE

=

37.78

MJ/m

3

Ws

- 50.7

MJ/

m

3

Instructions for the Installer

Engineers technical data

APPLIANCE CLASS : 3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar