56 KG

110719

REMOVABLE TRAY SUPPORT RACK FOR 20 GN1/1

4

1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW

1

INCLUDED ACCESSORIES

Power supply - V, phases, Hz

400 V, 3N, 50

Net weight - kg.

231

Noise level - dBA

72.5

installed-electric

2.558

Power - kW

at evaporation temperature - °C

-5

Refrigerant power

Refrigeration power - W

5363

Refrigerant quantity - g.

4000

Refrigerant type

R404a

Compressor power - HP

2.5

Max load capacity - trays h 65 mm - n°

12

Trays type

GN 1/1; 600x400

Door hinges

Right Side

N° and type of door

1

height

1500

depth

450

width

680

Internal dimensions - mm

height

2230

depth/with open doors

835, 1570

width

800

External dimensions - mm

Cooling unit

Built-In

Gross capacity (D.I.N. 8952) - l.

560

UK Guide lines - chilling / freezing

56

NF Regulations - chilling / freezing

43.2

Productivity per cycle - kg.

Power supply

Electric

BC56A

110719

CHARACTERISTICS

MODELS

TECHNICAL DATA

RANGE
COMPOSITION

Chilling means bringing the temperature of
cooked food from +90ºC to +3°C in a short
time lap to minimize bacteria proliferation and
avoid loss of food consistency and texture.
The ZANUSSI easyChill Blast Chillers reduce
temperature to +3°C at food core in less than
90 minutes. After the Blast Chilling a holding
cycle starts automatically to maintain food at
+3°C. Blast chilled food has a solid 5 days
shelf life without loss of flavour, nutritional
values and weight. The opportunity to
prepare in a single shot the food to be used
in different times during the week enables a
better work scheduling and therefore a
sensible reduction in labour costs.

FUNCTIONAL AND
CONSTRUCTION
FEATURES

�

Soft Chilling (Air temperature

–2°C).

�

Hard Chilling (Air temperature

–12°C).

�

All the probe-driven cycles feature

ARTE (Algorithm for Remaining
Time Estimation): the machine
displays the actual time needed to
end the cycle and to make planning
the activities easier.

�

Holding at +3°C (automatically

activated at the end of each cycle).

�

Turbo cooling: the chiller works

continuously at the desired
temperature. Ideal for continuous
production and for pastry application.

�

Automatic recognition of the

insertion of the food probe (cycles
piloted either by food probe
temperature or by time)

�

Single sensor core probe as

standard.