565 Trailer Sprayer - Operation Instructions

Section B

Fill Solution Tank, With Tank Agitation: Loading of
the solution tank, using tank agitation, is accomplished
via the following steps:
1. Close all valves.
2. Remove solution quick fill cap & connect load hose.
3. Open solution quick fill valve and the solution tank

main valve.

4. Open valve on loading reservoir (i.e. nurse tank).
5. Start the remote transfer pump.
6. Open the agitation valve.
7. Engage the liquid pump of the trailer sprayer.
8. Disengage the liquid pump of the trailer sprayer

when adequate agitation is achieved.

9. Run remote transfer pump until the desired amount

of solution is transferred into the trailer sprayer.

10. Close the agitation valve.
11. Close valves on loading reservoir.
12. Close the solution quick fill and the solution tank

main valves.

13. Remove load line and replace cap on sprayer quick

fill.

Fill Freshwater Rinse Tank
1. Close all valves.
2. Remove the freshwater rinse tank cap.
3. Fill tank to desired level.
4. Replace the freshwater rinse tank cap.

7

Section B

IMPORTANT

Turn off a hydraulically driven centrifugal pump using the “float” posi-
tion of the tractor’s hydraulic valve. This allows the motor to stop
slowly helping to protect the motor and motor seals.

Agitation Valve

Quick Fill Cap

Solution Quick

Fill Valve

Solution Tank

Main Valve

55 Gallon Fresh Water

Rinse Tank

Freshwater

Rinse Tank Cap