3-07

Spraying
Spraying is accomplished via the following steps:
1. Close all valves.
2. Open the the solution tank main valve.
3. Setup control system. (Setup and operation of the

control system is covered in the manual provided by
the controller manufacturer.)

4. Power ON the liquid pump of the trailer sprayer.
5. Open desired spray boom section valves.
6. Perform spraying according to the control system

provided.

7. To stop spraying, close all sprayboom section

valves.

8. Power OFF the liquid pump of the trailer sprayer.

Spraying with Agitation: Certain chemicals require
continuous agitation. If agitation is required during
spraying, open the agitation valve provided. If severe
foaming of your chemical occurs, check the chemical
label or your supplier to determine if agitation is required
or reduce the opening of the agitation valve to limit the
flow rate back to the solution tank. Reduce agitation if
adequate spray pressure cannot be maintained.

10

Section B

565 Trailer Sprayer - Operation Instructions

Section B

IMPORTANT

Turn off a hydraulically driven centrifugal pump using the “float” posi-
tion of the tractor’s hydraulic valve. This allows the motor to stop
slowly helping to protect the motor and motor seals.

Sprayboom Section Valves

Solution Tank

Main Valve

Handle

Solution Tank Main Valve

Agitation Valve