Zebra Z4M/Z6M Printers User’s Guide

45

Media and Ribbon Sensor Calibration
Performing the manual calibration procedure resets the sensitivity of the sensors to detect the media and
ribbon you are using more accurately. With the sensors at their new sensitivity, the printer then performs
the manual calibration. Changing the type of ribbon and/or media may require resetting the sensitivity of
the media and ribbon sensors.

Display Shows

Action/Explanation

SENSOR PROFILE

Sensor Profile: Press the INCREMENT (+) key to print a media sensor profile.
See Figure 23. The media sensor profile may be used to troubleshoot registration
problems that may be caused when the media sensor detects preprinted areas on
the media or experiences difficulty in determining web location. If the sensitivity of
the media and/or ribbon sensors MUST be adjusted, use the manual calibration
procedure.

MANUAL

CALIBRATION

Manual Calibration: Press the INCREMENT (+) key to start the calibration
procedure.
This procedure is used to reset the sensitivity of the media and ribbon sensors.
The manual calibration is then performed.