Cooling performance, Cooling capacity - with variable speed furnaces – York H*RC018 THRU 060 User Manual

Page 10

Advertising
background image

036-21137-003 Rev. A (1102)

10

Unitary Products Group

1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.

a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.

3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended

condensing temperature is 140°F.

H2RC048S06

P1DUC20V

G1FA048S21

21

1610

46.5

34.9

-

12.10

11.15

P1DUC20V

G2FD048(S,H)21

21

1610

46.5

34.9

-

12.25

11.05

P1XDD20V

G2FD048(S,H)24

24

1610

47.0

35.4

-

12.40

11.00

P1XUC16V

G1FA048S21

21

1480

46.0

34.4

-

12.10

10.90

P1XUC16V

G2FD048(S,H)21

21

1480

46.0

34.4

-

12.30

10.80

P1XUC20V

G1FA048S21

21

1590

46.5

34.9

-

12.10

11.10

P1XUC20V

G2FD048(S,H)21

21

1590

46.5

34.9

-

12.25

11.00

P1XUD20V

G1FA060S24

24

1560

48.5

36.5

-

13.00

11.45

P1XUD20V

G2FD048(S,H)24

24

1560

47.0

35.4

-

12.50

11.20

P1XUD20V

G2FD060(S,H)24

24

1560

48.5

36.5

-

13.00

11.45

H1RC048S(25,46)

P1DUC20V

G1FA048S21

21

1610

45.5

33.7

-

12.20

11.20

P1DUC20V

G2FD048(S,H)21

21

1610

45.5

33.7

-

12.25

11.40

P1XUC16V

G1FA048S21

21

1480

45.0

33.2

-

12.20

10.95

P1XUC16V

G2FD048(S,H)21

21

1480

45.0

33.2

-

12.30

11.10

P1XUC20V

G1FA048S21

21

1590

45.5

33.7

-

12.10

11.15

P1XUC20V

G2FD048(S,H)21

21

1590

45.5

33.7

-

12.25

11.35

P1XUD20V

G1FA060S24

24

1620

47.0

34.8

-

12.75

11.65

P1XUD20V

G2FD048(S,H)24

24

1620

45.5

33.7

-

12.25

11.30

P1XUD20V

G2FD060(S,H)24

24

1620

47.0

34.8

-

12.75

11.65

H3RC060S06

H1RC060S(25,46)

P1XDD20V

G2FD060(S,H)24

24

1805

57.0

42.6

-

11.50

10.00

P1XUC20V

G1FA060S21

21

1620

57.0

42.1

-

12.10

10.20

P1XUD20V

G1FA060S24

24

1620

57.0

42.1

-

12.10

10.40

P1XUD20V

G2FD060(S,H)24

24

1620

57.0

42.1

-

12.10

10.40

P1XUD20V

G2FD061

H

24

24

1800

58.0

43.2

-

12.10

10.55

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2. TXV = Use 1TV700 Series Kit.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.

COOLING PERFORMANCE

MODEL

SUCT. T/P

@ COMPR.

AIR TEMP ON CONDENSER

MODEL

SUCT. T/P

@ COMPR.

AIR TEMP ON CONDENSER

75°F

95°F

115°F

75°F

95°F

115°F

TEMP. PSIG MBH KW MBH KW MBH KW

TEMP. PSIG MBH KW MBH KW MBH KW

H2RC018S06

35

61.5

17.19 1.44 13.89 1.59

11.63

1.70

H2RC042S06

35

61.5

35.94 3.12 31.92 3.76 27.86 4.54

40

68.5

18.77 1.45 15.80 1.63 13.53 1.77

40

68.5

39.29 3.15

35.11

3.77 30.80 4.55

45

76.0

20.48 1.47 17.70 1.66 15.04 1.83

45

76.0

42.48 3.21 38.17 3.84 33.70 4.63

50

84.0

21.99 1.48 19.60 1.70 16.81 1.89

50

84.0

45.62 3.23 41.40 3.92 36.56 4.39

H2RC024S06

35

61.5

20.81 1.81 16.82 2.00 14.07 2.14

H2RC048S06

35

61.5

40.62 3.39 36.09 4.08 31.50 4.91

40

68.5

22.73 1.83 19.13 2.05 16.37 2.23

40

68.5

44.42 3.41 39.69 4.09 34.83 4.94

45

76.0

24.80 1.85 21.43 2.09 18.20 2.31

45

76.0

48.02 3.47 43.16 4.16 38.10 5.02

50

84.0

26.63 1.86 23.73 2.14 20.36 2.37

50

84.0

51.58 3.50 46.81 4.25 41.33 4.76

H2RC030S06

35

61.5

26.48 2.34 21.42 2.59 17.91 2.77

H1RC048S(25,46)

35

61.5

39.75 3.32 35.31 3.99 30.82 4.81

40

68.5

28.94 2.36 24.34 2.65 20.84 2.92

40

68.5

43.46 3.34 38.84 4.00 34.08 4.83

45

76.0

31.56 2.39 27.07 2.71 23.17 2.96

45

76.0

46.99 3.40 42.23 4.07 37.28 4.91

50

84.0

33.89 2.40 30.20 2.77 25.92 3.07

50

84.0

50.47 3.43 45.80 4.16 40.44 4.66

H2RC036S06

35

61.5

29.38 2.76 23.75 3.06 19.87 3.26

H3RC060S06

H1RC060S(25,46)

35

61.5

50.26 4.42 44.64 5.32 38.97 6.42

40

68.5

32.09 2.78 27.00 3.13 23.12 3.40

40

68.5

54.95 4.46 49.10 5.33 43.08 6.44

45

76.0

35.01 2.81 30.25 3.19 25.70 3.51

45

76.0

59.41 4.54 53.38 5.43 47.13 6.55

50

84.0

37.59 2.83 33.50 3.26 28.74 3.62

50

84.0

63.81 4.58 57.90 5.55 51.13 6.22

H1RC036S(25,46)

35

61.5

29.20 2.70 23.61 2.99 19.75 3.19

40

68.5

31.90 2.72 26.84 3.06 22.98 3.32

45

76.0

34.80 2.75 30.07 3.12 25.54 3.43

50

84.0

37.36 2.77 33.30 3.19 28.57 3.54

COOLING CAPACITY - With Variable Speed Furnaces

UNIT MODEL

VARIABLE SPEED
FURNACE MODEL

COIL MODEL

1

W

COOLING

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

2

EER

TOTAL

SENS.

Advertising