Adjust and Calibrate Sensors
11342L Rev. 8 6/4/2004
105SL User Guide
37
7.
Close the printhead, trapping the ribbon in this position.
8.
Press the (+) key. The LCD shows “CALIBRATING PLEASE WAIT.”
9.
When this part of the calibration process is completed, the LCD reads “RELOAD ALL
CONTINUE.”
10.
Open the printhead. Pull the liner until a label is positioned between the media sensors.
11.
Return the ribbon to its proper position.
12.
Close the printhead. Press the (+) key to perform the next part of the calibration sequence.
“MEDIA AND RIBBON CALIBRATE” displays. The printer is calibrated when the
media stops feeding.
13.
Press SETUP/EXIT to leave Setup Mode. Choose “permanent” when SAVE CHANGES
displays.
14.
Press NEXT/SAVE to save the changes.
The printer does a calibration equivalent to pressing
CALIBRATE
; during this process,
the printer determines the label length. To see the new readings on the new scale, print a
sensor profile.