Multipliers for determining the performance with other indoor sections.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

LOW CFM

HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZH06011

INDOOR COIL MODEL NO.

FC/MC62D + MV20D

AIR TEMP.

ENTERING
OUTDOOR

UNIT

AIR TEMP.

ENTERING

INDOOR

COIL

ID CFM

1066

1116

1166

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

60

60

50.9 3.5 4.3 51.1 3.4 4.4 51.2 3.4 4.5

70

50.1 3.9 3.8 50.2 3.8 3.9 50.4 3.7 4.0

80

49.3 4.2 3.4 49.4 4.1 3.5 49.6 4.1 3.6

47

60

41.8 3.3 3.7 41.9 3.3 3.7 41.9 3.2 3.8

70

41.3 3.7 3.3 41.3 3.6 3.3 41.3 3.6 3.4

80

40.7 4.1 2.9 40.8 4.0 3.0 40.8 3.9 3.0

40

60

37.0 3.3 3.3 36.9 3.2 3.4 36.8 3.2 3.4

70

36.9 3.6 3.0 36.9 3.6 3.0 36.9 3.5 3.1

80

36.9 4.0 2.7 36.9 4.0 2.7 36.9 3.9 2.8

30

60

31.3 3.2 2.9 31.3 3.1 2.9 31.3 3.1 3.0

70

31.3 3.5 2.6 31.4 3.5 2.6 31.4 3.5 2.7

80

31.4 3.9 2.4 31.5 3.9 2.4 31.5 3.8 2.4

17

60

24.2 3.0 2.3 24.3 3.0 2.4 24.3 3.0 2.4

70

24.8 3.5 2.1 25.0 3.5 2.1 25.2 3.5 2.1

80

25.4 4.0 1.9 25.7 3.9 1.9 26.0 3.9 1.9

10

60

21.0 3.0 2.1 21.0 2.9 2.1 21.1 2.9 2.1

70

21.6 3.5 1.8 21.8 3.5 1.8 22.0 3.5 1.9

80

22.2 4.0 1.6 22.6 4.0 1.7 23.0 4.0 1.7

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Air Handler

Coil

MBH

KW

COP

AV/SV60

-

1.00 1.00 1.00

MV20D

1.00 1.00 1.00

Variable Speed
Furnace

Coil

T.C.

S.C.

KW

P(C,V)8*C20

FC/PC60C

1.00 0.98 1.02

P(C,V)9*C20

FC/PC60C

0.98 0.98 1.02

P(C,V)9*D20

FC/MC/PC60D

0.98 0.98 1.02

P(C,V)8*C20

FC/MC62D

1.00 0.98 1.02

P(C,V)9*C20

FC/MC62D

0.98 0.98 1.02

P(C,V)9*D20

FC/MC62D

0.98 0.98 1.02