Operation – Xantrex Technology FP 3000-12 User Manual

Page 9

Advertising
background image

9

OPERATION

• When the LED is blinking slowly (once

per second), an over-current condition or a
short circuit has occured. The system has
shut OFF and will not automatically restart.
Correct the fault condition and manually restart
the system.

LOW BATTERY & OVERTEMP/OVERLOAD
- Red LEDs

• When both LEDs are blinking, an AC

backfeed has been detected. A backfeed occurs
when AC power from an external source is
connected to the output of the inverter. Inspect
wiring for a possible input/output wiring error.
This condition will damage the unit and must
be corrected before further operation.

TSC (Temperature Sensitive Charging)

This provides for the connection of a sensor to
measure battery temperature for compensated
charging. If no sensor is connected the charge
voltage levels are set to defaults based on
battery type.

OPTIONAL REMOTES

If using a remote, refer to the installation
instructions included with the remote.

Note: When a Remote Control Panel is installed,
the jumper included in the parts plastic bag is
not used in the Auxiliary Switch Port (AUX
SWITCH) on the front panel of the inverter/
charger. See page 23 for more details.

Remote

TSC

Overtemp

Low
Battery

Auxiliary Port

Advertising