Yamaha RX-V757 User Manual

Page 30

Advertising
background image

28

AUTO SETUP

■

Troubleshooting for auto setup procedure

Before auto setup

Errors during auto setup

Error message

Cause

Remedy

Connect MIC

Optimizer microphone is not connected.

• Connect the supplied optimizer microphone to the

OPTIMIZER MIC jack on the front panel.

Unplug HP

Headphones are connected.

• Unplug the headphones.

Error message

Cause

Remedy

E-1:NO FRONT SP

Front L/R channel signal(s) is (are) not
detected.

• Select the front speakers with SPEAKERS A/B.
• Check the front left and right speaker connections.
• Turn on the power to the external amplifier (when the

front speaker signals are output from an external
amplifier).

E-2:NO SURR. SP

Only one surround channel signal is detected.

• Check the surround speaker connections.

E-3:NO PRES. SP

Only one presence channel signal is detected.

• Check the presence speaker connections.

E-4:SBR->SBL

Only right surround back channel signal is
detected.

• Connect the surround back speaker to the LEFT

SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.

E-5:NOISY

Background noise is too loud.

• Try the auto setup procedure in a quiet environment.
• Turn off noisy electric equipment like air conditioners

(etc.) or move them away from the optimizer
microphone.

E-6:CHECK SUR.

Surround back speaker(s) is (are) connected,
though surround L/R speakers are not.

• Connect surround speakers when you use (a)

surround back speaker(s).

• Check the surround speaker connections.

E-7:NO MIC

The optimizer microphone was unplugged
during the auto setup procedure.

• Do not touch the optimizer microphone during the

auto setup procedure.

E-8:NO SIGNAL

The optimizer microphone does not detect test
tones.

• Check the microphone setting.
• Check the speaker connections and placement.

E-9:USER CANCEL

The auto setup procedure was cancelled due to
user activity.

• Perform the auto setup procedure again. Do not adjust

VOLUME (etc.) during the auto setup procedure.

E-10:INTERNAL
ERROR

A DSP communication error or hangup
occurred.

• Perform the auto setup procedure again.