SOUND LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

* Rated in accordance with ARI 270-2008 Standards.

TYPICAL INSTALLATION

TYPICAL FIELD WIRING

Size

Test Condition

63

125

250

500

1000

2000

4000

8000

dBA

SQI

RSS Sound Power Calibration 1091 402

82.8

85.4

85.9

85.3

88.1

88.6

86.6

83.9

18

Cooling Mode

67.3

69.2

64.6

67.3

65.5

61.5

58.2

51.8

70.0

19.21

Heating Mode

68.9

69.0

64.0

66.4

66.6

59.6

56.4

52.6

69.7

19.17

24

Cooling Mode

69.9

73.1

64.2

65.2

66.3

61.2

58.8

52.4

69.9

19.03

Heating Mode

72.4

71.6

64.8

68.3

68.0

62.2

60.1

53.0

71.6

18.99

30

Cooling Mode

70.5

68.8

64.3

65.3

65.5

60.3

55.8

50.6

69.0

19.01

Heating Mode

72.2

70.1

67.5

66.7

69.4

62.5

58.3

52.7

72.0

19.03

36

Cooling Mode

70.9

69.3

65.3

66.4

66.3

59.7

56.7

50.8

69.6

19.14

Heating Mode

73.2

70.1

66.9

68.5

68.4

61.6

59.4

55.5

71.7

19.12

42

Cooling Mode

71.7

69.5

72.1

69.0

71.3

60.6

56.9

54.0

73.3

19.01

Heating Mode

72.6

72.6

68.1

70.5

70.9

62.7

59.2

56.9

73.6

19.02

48

Cooling Mode

71.0

71.0

68.4

68.1

67.9

60.1

55.8

51.3

70.8

19.11

Heating Mode

73.6

72.5

74.0

73.6

75.8

64.0

63.2

56.8

77.6

19.08

60

Cooling Mode - High Stage

71.2

69.4

71.4

73.2

71.2

61.1

57.6

52.8

74.7

19.09

Heating Mode - High Stage

71.6

72.7

69.6

71.3

72.4

63.4

61.5

57.4

75.0

19.05

THERMOSTAT

SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT

TO INDOOR COIL

TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK

NEC CLASS 2 WIRING

NEC CLASS 1 WIRING

ALL OUTDOOR WIRING
MUST BE WEATHERPROOF.

CONTROL
ACCESS
PANEL

WEATHERPROOF
DISCONNECT
SWITCH

MINIMUM 24” SERVICE
ACCESS CLEARANCE
ON ONE SIDE

48” OVERHEAD
CLEARANCE

10” CLEARANCE
AROUND PERIMETER

NOTE:

THERMOSTAT

INDOOR UNIT

OUTDOOR UNIT

LOW VOLTAGE TERMINAL BLOCK
IN AIR HANDLER WITH ELECTRIC HEAT

DEFROST
CONTROL

FIELD
INSTALLED
JUMPER

DEHUMIDIFICATION CONTROL CONNECTION
(Humidistat* Jumper must be removed)

GND.

SCREW

CONTACTOR

T2

T1

L2

L1

M

R

L or X

Y

O

W

G

T

2

E

2

R

R

Y

Y

O

O

W2

W

W1

C

C

X/L

G

W1

BK

GND.

LUG

CIRCUIT
BREAKER***

POWER WIRING
24V CONTROL WIRING
(NEC CLASS 2)

JUMPER TERMINALS E AND W TO HEAT
ON FIRST STAGE DURING EMERGENCY HEAT.

TERMINAL NOT USED ON ALL THERMOSTATS.

POWER WIRING

208/230-1-60

230-1-50

CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS.
CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER.

B or C

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

RED

BLK

YEL

ORG

BRN

PUR

WHT

CC

GRY

/66

GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS.

5

1

2

3
4

5

1

3,4