York SPLIT-SYSTEM YHJF18 THRU 60 User Manual

Page 7

Advertising
background image

510667-YTG-B-0509

Johnson Controls Unitary Products

7

\

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.

HEATING PERFORMANCE - With Air Handler

UNIT

MODEL*

AIR

HANDLER

COIL

1

MODEL

ARI HEATING

2

47

F

17

F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

14.5 SEER HP WITH MV - VARIABLE SPEED

YHJF18S41S1

MV12B

FC/MC35B

18.0

3.76

1.40

11.0

2.48

1.30

8.50

MV12B

FC/MC43B

18.0

3.90

1.35

10.9

2.56

1.25

8.50

YHJF24S41S1

MV12B

FC/MC35B

22.2

3.68

1.77

14.9

2.46

1.77

8.50

MV12B

FC/MC43B

22.2

3.82

1.70

14.9

2.54

1.72

8.50

YHJF30S41S1

MV12B

FC/MC43B

30.0

3.88

2.27

18.8

2.68

2.06

9.00

MV16C

FC/MC43C

30.0

3.92

2.24

18.8

2.70

2.04

9.00

YHJF36S41S1

MV12B

FC/MC43B

36.0

3.74

2.82

24.4

2.52

2.84

8.20

MV16C

FC/MC43C

36.0

3.74

2.82

24.2

2.52

2.81

9.00

YHJF42S41S1

MV20D

FC/MC62D

40.5

4.02

2.95

26.0

2.76

2.76

9.00

YHJF48S41S1

MV20D

FC/MC62D

48.0

3.82

3.68

31.8

2.60

3.58

9.00

14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED

YHJF18S41S1

AV*36

–

18.0

3.98

1.33

10.8

2.62

1.21

8.50

YHJF24S41S1

AV*36

–

22.0

3.70

1.74

14.8

2.50

1.73

8.50

YHJF30S41S1

AV*36

–

29.8

3.98

2.19

18.6

2.74

1.99

9.00

YHJF36S41S1

AV*36

–

36.0

3.78

2.79

24.2

2.54

2.79

9.00

14.5 SEER HP WITH AHP / SHP / AHX / F*FP

YHJF18S41S1

AHX30

–

18.0

3.88

1.36

10.9

2.52

1.27

8.50

YHJF24S41S1

AHX30

–

22.2

3.64

1.79

13.7

2.42

1.66

8.50

F6FP030

–

22.2

3.64

1.79

15.1

2.42

1.83

8.20

F6FP036

–

22.2

3.68

1.77

15.0

2.46

1.79

8.50

AHX36

–

22.4

3.70

1.77

15.1

2.46

1.80

8.50

YHJF30S41S1

AHX36

–

30.0

4.00

2.20

18.7

2.76

1.99

9.00

F6FP042

–

30.0

4.00

2.20

18.7

2.76

1.99

9.00

YHJF36S41S1

AHX36

–

36.0

3.82

2.76

24.2

2.56

2.77

9.00

AHX42

–

36.0

3.84

2.75

22.2

2.56

2.54

9.00

F6FP042

–

36.0

3.88

2.72

24.4

2.60

2.75

9.00

YHJF42S41S1

AHX60

–

40.5

4.00

2.97

26.0

2.74

2.78

9.00

F6FP060

–

41.0

4.04

2.97

26.2

2.74

2.80

9.00

YHJF48S41S1

AHX60

–

48.0

3.82

3.68

31.6

2.60

3.56

9.00

F6FP060

–

48.0

3.82

3.68

31.6

2.60

3.56

9.00

See notes below.

HEATING CAPACITY - With Air Handler Coils

UNIT

MODEL

AIR

HANDLER

COIL

1

MODEL

HEATING

2

STAGE

RATED

CFM

NET MBH

HSPF

COP @ 47

47 OD

17 OD

14.5 SEER HP WITH MV - VARIABLE SPEED

YHJF60S41S1

MV20D

FC/MC62D

1

1160

43.0

–

–

–

2

1855

57.0

40.5

9.00

3.66

2

1160

54.9

39.0

8.85

3.04

14.5 SEER HP WITH AHX

YHJF60S41S1

AHX60

–

1

1160

43.1

–

–

–

2

1855

58.0

40.0

9.00

3.72

2

1170

57.5

40.0

8.90

3.24

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.