Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

YMA04811

INDOOR COIL MODEL NO.

G2FA060S24

CONDENSER

ENTERING AIR

TEMPERATURE

ID CFM

1400

1600

1800

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

62

62

67

72

57

65

T.C.

42.8 45.7 45.8 50.3 57.2 44.6 47.0 47.0 51.5 57.3 46.3 48.3 48.1 52.8 57.5

S.C.

43.7 41.4 35.6 35.2 27.3 45.4 44.0 37.9 37.8 28.8 47.1 46.5 40.3 40.3 30.4

K.W.

3.1 3.1 3.1 3.2 3.2 3.1 3.1 3.1 3.2 3.2 3.1 3.1 3.1 3.2 3.2

75

T.C.

41.6 44.2 44.2 48.5 54.2 43.3 45.4 45.3 49.7 54.8 44.9 46.7 46.4 50.9 55.4

S.C.

42.4 40.8 34.9 34.6 27.1 44.1 43.1 37.2 37.0 28.5 45.7 45.5 39.5 39.5 29.8

K.W.

3.5 3.6 3.6 3.6 3.7 3.5 3.6 3.6 3.6 3.7 3.6 3.6 3.6 3.6 3.7

85

T.C.

40.4 42.7 42.6 46.7 51.3 42.0 43.9 43.6 47.8 52.3 43.6 45.1 44.7 48.9 53.4

S.C.

41.2 40.1 34.2 34.0 26.9 42.7 42.3 36.5 36.3 28.1 44.3 44.5 38.8 38.6 29.3

K.W.

4.0 4.0 4.0 4.1 4.1 4.0 4.0 4.0 4.1 4.1 4.0 4.0 4.0 4.1 4.1

95

T.C.

39.2 41.2 41.0 45.0 48.3 40.7 42.3 42.0 46.0 49.8 42.2 43.5 43.0 47.0 51.3

S.C.

40.0 39.4 33.6 33.4 26.7 41.4 41.4 35.8 35.6 27.7 42.9 43.4 38.1 37.8 28.7

K.W.

4.4 4.4 4.4 4.5 4.5 4.4 4.4 4.4 4.5 4.6 4.4 4.5 4.5 4.5 4.6

105

T.C.

37.7 39.3 39.0 42.9 46.4 39.1 40.4 39.9 43.8 47.7 40.5 41.5 40.8 44.7 48.9

S.C.

38.4 38.2 32.6 32.6 25.6 39.8 39.9 34.9 34.8 26.8 41.1 41.6 37.1 37.0 27.9

K.W.

5.1 5.1 5.1 5.1 5.2 5.1 5.1 5.1 5.1 5.2 5.1 5.1 5.1 5.2 5.2

115

T.C.

36.2 37.4 37.0 40.8 44.6 37.6 38.5 37.9 41.7 45.6 38.9 39.5 38.7 42.5 46.6

S.C.

37.0 37.0 31.7 31.8 24.5 38.3 38.4 33.9 34.0 25.8 39.4 39.8 36.1 36.3 27.2

K.W.

5.7 5.7 5.7 5.8 5.8 5.7 5.7 5.7 5.8 5.8 5.8 5.8 5.7 5.8 5.8

125

T.C.

34.8 35.5 35.0 38.8 42.8 36.0 36.6 35.8 39.6 43.5 37.2 37.6 36.6 40.3 44.2

S.C.

35.5 35.8 30.8 31.0 23.4 36.8 36.9 33.0 33.2 24.9 37.7 38.0 35.2 35.5 26.4

K.W.

6.3 6.3 6.3 6.4 6.4 6.4 6.4 6.3 6.4 6.5 6.4 6.4 6.3 6.4 6.5

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Air Handler

Coil

T.C.

S.C.

KW

F2FP045

0.99 0.97 0.99

F2FP/F3FP060

0.99 0.96 1.01

F2FV060

1.00 0.98 0.96

N1VSD20

G2FD060(S,H)24(T)

1.00 0.98 0.96

N1VSD20

G2FD061H24

1.01 0.99 0.96

N1AHD20

G2FD060(S,H)24(T)

1.00 1.00 1.00

N1AHD20

G2FD061H24

1.00 1.01 1.00

G1FA060S21,24(T)

1.00 1.00 1.00

G2FD060(S,H)24(T)

1.00 1.00 1.00

G2FD061H24

1.00 1.01 1.00

G1NA060S24T

0.99 0.98 1.00

G1HD060

0.98 0.98 0.99

G1HA60H24(T)

0.99 0.98 0.99

Variable Speed
Furnace

Coil

T.C.

S.C.

KW

P*DUC20V

G1FA060S21(T)

1.00 1.01 0.98

P*DUC20V

G2FD060(S,H)24(T)

1.00 1.01 0.98

P*DUC20V

G2FD061H24

1.01 1.02 0.99

P1XUC16V

G1FA060S21(T)

1.00 1.00 1.00

P1XUC16V

G2FD060(S,H)24(T)

1.00 1.00 1.00

P1XUC16V

G2FD061H24

1.00 1.01 0.99

P1XUC20V

G1FA060S21(T)

1.00 1.00 0.99

P1XUC20V

G2FD060(S,H)24(T)

1.00 1.00 0.99

P1XUC20V

G2FD061H24

1.01 1.01 0.99

P1XUD20V

G1FA060S24(T)

1.00 1.01 0.99

P1XUD20V

G2FD060(S,H)24(T)

1.00 1.01 0.99

P1XUD20V

G2FD061H24

1.01 1.02 0.98

P1XDC20V

G2FD060(S,H)24(T)

0.99 0.99 0.98

P1XDC20V

G1HA60H24(T)

0.99 0.98 0.97

P1XDD20V

G2FD060(S,H)24(T)

1.00 1.01 0.99

P1XDD20V

G2FD061H24

1.01 1.02 0.99

P1XDD20V

G1HA60H24(T)

0.99 0.98 0.97

Advertising