Rs-422a serial interface (ccitt v.11 and x.27) – Xerox 4505/4505ps User Manual

Page 214

Advertising
background image

C a b l e S p e c i f i c a t i o n s

A-12

4 5 0 5 / 4 5 0 5 p s o r 4 5 1 0 / 4 5 1 0 p s U s e r ’ s G u i d e

The RS-422A Serial Interface is hardware compatible with

the EIA RS-422 standard which defines the interconnect of

Data Terminal Equipment (DTE) and Data Communication

Equipment (DCE).

Data Rates

The user may select line speeds of 300, 600, 1200, 2400, 4800,

9600, 19200 and 38400 baud.

Default setting is for 9600 baud

.

Encoding

Asynchronous communication in the printers supports 7 or

8-bit ASCII data. The string of data bits is encapsulated by 1

Start bit, 1 or 2 Stop bits and may have an appended Parity

bit. Parity (even, odd or none), the number of stop bits and 7

or 8 bit data are selectable from the front panel UI.

Default

settings are for 8 bit data with 1 stop bit and parity none

.

Protocols

XON/XOFF provides the software handshaking on the

RS-422 interface.

Robust XON/XOFF

is the default

.

Connections

The connector for the RS-422A interface is the 25 pin “D”

Shell type. The use of short cables for interconnect is

recommended. Cable length has been certified at 4 feet.

RS-422A Serial

Interface (CCITT

V.11 and X.27)

AUG-APPA Page 12 Black,Cyan Saturday, January 21, 1995 7:07 PM