background image

Operating Modes

975-0004-01-02 Rev D

3

•

Indoor-type, powder-coated enclosure, for wall
mounting.

•

Conformal-coated circuit boards, plated terminals,
powder-coated metal components, and stainless steel
fasteners improves tolerance to hostile environments.

•

Meets National Electrical Code (NEC) and other
international controller specifications.

•

The C35, C40 and C60 models are UL listed to the
U.S. UL Standard 1741 (1st edition), and Canada
(CSA-C22.2 No. 107.1-95).

•

2-year limited warranty.

Operating Modes

The DC controller is a critical component in any solar, wind
or hydro power generation system and protects the batteries
from over-discharge and over-charge conditions. The

C-Series

has two operating modes (Charge Control mode and

Load Control mode determined by the Operating mode
jumper (See Figure 2-5). These two different operating
modes allow the C-Series to be installed and function as three
different DC controllers.

•

Charge Control Mode

• PV Charge Controller - controls charging in PV

installations.

• Diversion Controller – used in PV, wind, or hydro

installations to divert any excess energy to a diversion
load and in the case of a wind or hydro generator, helps
to prevent over-spin damage.

•

Load Control Mode

• Load Controller - prevents damage to the battery from

over-discharge during periods of poor charging or
excessive loads.