Charge Control or Diversion Control Indications
(Green)

The flashing rate of the LED indicates the controller’s stage
of operation and approximate battery voltage.

•

One to four flashes indicates the controller is in the Bulk
stage. As the flashing rate increases, the batteries are
progressively closer to the Bulk voltage. Table 3-1
indicates the approximate level the battery is below the
Bulk setting.

•

Five flashes indicates the controller has reached Bulk
voltage and is in the Absorption stage.

•

Solid green means the controller is in the Float stage and
is regulated at the Float voltage.

Table 3-1 Battery Voltage LED Indicators

Green LED

(Charge/Diversion Mode)

LED

Status

Red LED

(Load Control Mode)

Battery at FLOAT Setting

Always
ON

Battery at LVD Setting

(for 6 minutes = LVD)

Battery at BULK Setting

5 blinks

> 0.15
above
LVD

>0.03
above
LVD

>0.45
above
LVD

BULK Setting Minus (–)

LVD Setting Plus (+)

0.25 Vdc

0.50 Vdc

1.00 Vdc

4 blinks

0.15 Vdc

0.30 Vdc

0.45 Vdc

0.50 Vdc

1.00 Vdc

2.00 Vdc

3 blinks

0.30 Vdc

0.60 Vdc

0.90 Vdc

0.75 Vdc

1.50 Vdc

3.00 Vdc

2 blinks

0.45 Vdc

0.90 Vdc

1.35 Vdc

> 0.75
below Bulk

> 1.50
below Bulk

> 3.00
below Bulk

1 blink

> 0.45
below Bulk

> 0.90
below Bulk

> 1.375
below Bulk

12 volts

24 volts

48 volts

DC
Voltage

12 volts

24 volts

48 volts