Problem
Possible solution
Noise
• It is normal for some metal parts on the cooker to
produce noise when in use, this is due to expansion
and contraction when heating up and cooling down.
Technical Data
Dimensions
Height:
900mm (nominal)
Width:
500mm (nominal)
Depth:
600mm (nominal)
Weight:
47.3Kg
Space for fixing at hob level
2mm minimum clearance
Space for fixing above hob level
See important note location of appliance
Minimum space above hob level
787mm (If a cooker hood is fitted refer to the cooker-
hood installation instructions)
Connections
Gas connection
Rear left hand side of appliance at hob level. Rc ½" ( ½
" B.S.P. female)
Electrical connection
None
Ignition
Battery 1.5 Volt AA size
GAS CONSUMPTION TABLE
LPG
GB: I3+
IE: I3+
NG
GB: I2H
LARGE BURNER
INJECTOR
85
115
NOMINAL RATING (KW)
3
3
CONSUMPTION IN 1h
218.3 gr/h
285.7 lt/h
MEDIUM BURNER
INJECTOR
65
97