Ns i gr – Xpelair DX200 User Manual

Page 5

Advertising
background image

Tilbehør
For å forenkle installasjonen og
spare tid, kan det være at din
installasjon krever noe av
tilbehøret som er listet opp
nedenfor:

WD100

Vegg-gjennomføring

CFWG100 Vegg-gitter
FDA

Utstyrspakke med
plant kanaladapter

XCT100

Kondensavskiller

DGW/B

Gitterluke for
luftutskiftning

SP100

Muffeplate

XAA

Luftadapter for mur

VC10

Avtrekksdeksel

WT10

Kanalavslutnings-sett

XF/FM

Plan rørkanal
(plast/metall)
(plast 234 x 29 mm
metall 230 x 25 mm)

VK10

Veggventil-sett

FD100

Fleksibel rørkanal

WDC5

Snekkeskrue-klips

XCMK

Sett for montering i
himling

XBP

In-line
tilbakeslippsklaff

EFT

Lettmontert
avslutnings-sett

GMK

Sett for montering i
vindu

PDXGF

Fettfilter

Nedenfor er det listet opp enkelte
reservedeler som er tilgjengelige.
Se baksiden på denne trykksaken
for bestillingsinformasjon:

41520SK Monterings-sett

(komplett)

41528SK Rund muffe (komplett)
41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/

DX200T)

41782SK Kretskort-komponent

(DX200T)

41735SK Kretskort-komponent

(CF20)

41736SK Kretskort-komponent

(CF20T)

41737SK Frontdeksel kompl.

med mottrykksplate
(DX200)

41738SK Frontdeksel kompl. med

mottrykksplate (DX200T)

41739SK Frontdeksel kompl. med

mottrykksplate
(CF20/CF20T)

41740SK Innfatningsprofil

(komplett)

41741SK Snorbryter-komponent

(CF20/CF20T)

41742SK Viftehjul (komplett)

Tillbehör
I listan nedan hittar du hjälpmedel
som kan vara av nytta under
installationen:

WD100

Väggtrumma

CFWG100 Väggaller
FDA

Adaptorsats för
planmontering

XCT100

Kondensavledare

DGW/B

Luftregleringsgaller

SP100

Mufförbindningsplatta

XAA

Adapter

VC10

Ventilhuv

WT10

Avspänningssats

XF/FM

Planmontering
(plast/metall)
(plast 234 x 29 mm)
(metall 230 x 25 mm)

VK10

Väggventilsats

FD100

Flexibel
ledningsdragning

WDC5

Skruvdriftsklämmor

XCMK

Takmonteringssats

XBP

Svart reglerventil

EFT

Avspänningssats

GMK

Glasmonteringssats

PDXGF

Smörjningsfilter

I listan nedan hittar du
reservdelar. Du hittar
beställningsinformation på denna
bruksanvisnings baksida:

41520SK Fastsättningssats

(komplett)

41528SK Mufförbindning

(komplett sortiment)

41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/

DX200T)

41782SK PCB-montering

(DX200T)

41735SK PCB-montering

(CF20)

41736SK PCB-montering

(CF20T)

41737SK Främre skydd med

skärm (DX200)

41738SK Främre skydd med

skärm (DX200T)

41739SK Främre skydd med

skärm (CF20/CF20T)

41740SK Ramformning

(komplett sortiment)

41741SK Dragsnöresmontering

(CF20/CF20T)

41742SK Fläkthjul (komplett

sortiment)

Accessori opzionali
Per un’installazione più facile e
veloce, potrebbero essere
necessari alcuni degli accessori
sottoelencati:

WD100

Condotto per parete

CFWG100 Grata per parete
FDA

Kit adattatore per
condotto piatto

XCT100

Pozzetto di
intercettazione della
condensa

DGW/B

Grata dello sportello di
ricambio aria

SP100

Piastra di imbocco

XAA

Adattatore per mattoni
traforati

VC10

Cappottatura di
ventilazione

WT10

Kit di terminazione
condotti

XF/FM

Condotti piatti
(plastica/metallo)
(plastica 234 x 29mm,
metallo 230 x 25mm)

VK10

Kit di ventilazione per
parete

FD100

Condotti flessibili

WDC5

Fermagli a vite senza
fine

XCMK

Kit di montaggio al
soffitto

XBP

Otturatore in linea del
tiraggio di ritorno

EFT

Kit di terminazione di
facile montaggio

GMK

Kit per il montaggio su
vetro

PDXGF

Filtro antigrasso

Qui di seguito sono elencati alcuni
dei ricambi disponibili. Per
informazioni su come ordinarli,
consultare la quarta di copertina:

41520SK Kit di fissaggio (kit

intero)

41528SK Imbocco a bicchiere

circolare (intera
gamma)

41731SK Motorino (DX200)
41733SK Motorino (CF20/

CF20T/DX200T)

41782SK Gruppo PCB

(DX200T)

41735SK Gruppo PCB (CF20)
41736SK Gruppo PCB (CF20T)
41737SK Coperchio anteriore

completo di
diaframma (DX200)

41738SK Coperchio anteriore

completo di
diaframma (DX200T)

41739SK Coperchio anteriore

completo di
diaframma
(CF20/CF20T)

41740SK Modanatura della

cornice
(intera gamma)

41741SK Gruppo cordicella

(CF20/CF20T)

41742SK Girante (intera

gamma)

Συµπληρωµατικές Επιλ γές
Για γρήγ ρη και εύκ λη
εγκατάσταση, η εγκατάσταση
σας µπ ρεί να ρειαστεί µερικά
απ τα Συµπληρωµατικά π υ
ανα έρ νται πι κάτω:
WD100

Αγωγ ς τ ί

υ

CFWG100 Κιγκλίδωµα τ ί

υ

FDA

Πρ σαρµ γέας
επίπεδ υ αγωγ ύ

XCT100

Ατµ παγίδα

DGW/B

Κιγκλίδωµα π ρτας
ανανέωσης αέρα

SP100

Πλάκα ύσµατ ς

XAA

Πρ σαρµ γέας
τ ύ λ υ αέρα

VC10

Κάλυµµα αεραγωγ ύ

WT10

Σύν λ αγωγ ύ
τερµατισµ ύ

XF/FM

Επίπεδ ς αγωγ ς
(πλαστικ /µέταλλ )
(Πλαστικ 234 29 λστ.
Μέταλλ 230 25 λστ.)

VK10

Σύν λ αεραγωγ ύ
τ ί

υ

FD100

Εύκαµπτ ς αγωγ ς

WDC5

Κλιπ

ι ειδ ύς

κίνησης

XCMK

Σύν λ τ π θέτησης
σε τα άνι

XBP

Φρά της

πισθ δρ µικ ύ

ρεύµατ ς in-line

EFT

Σύν λ
τερµατισµ ύ
εύκ λης ε αρµ γής

GMK

Σύν λ τ π θέτησης
γυαλι ύ

PDXGF

Φίλτρ γράσ υ

Πι κάτω ανα έρ νται µερικά
απ τα διαθέσιµα ανταλλακτικά.
Συµ

υλευθείτε την πίσω ψη

τ υ παρ ντ ς υλλαδί υ για
λεπτ µέρειες παραγγελίας:
41520SK Σύν λ στερέωσης

( λ κληρ σύν λ )

41528SK Κυκλικ ύσµα
41731SK Μ τέρ (DX200)
41733SK Μ τέρ (CF20/CF20T/

DX200T)

41782SK Σύν λ PCB (DX200T)
41735SK Σύν λ PCB (CF20)
41736SK Σύν λ PCB (CF20T)
41737SK Μπρ στιν κάλυµµα

συν δευ µεν απ
εκτρ πέα (DX200)

41738SK Μπρ στιν

κάλυµµα
συν δευ µεν απ
εκτρ πέα (DX200T)

41739SK Μπρ στιν κάλυµµα

συν δευ µεν απ
εκτρ πέα (CF20/CF20T)

41740SK

υτ πλαίσι

( λ κληρη σειρά)

41741SK Σύν λ κ ρδ νι ύ

τρα ήγµατ ς
(CF20/CF20T)

41742SK Στρ

εί

( λ κληρη σειρά)

N

S

I

GR

For speed and ease of Installation, your installation may require some of the
Ancillaries indicated in “Ancillary Options”.

If installing on a wall (surface mounting)

1.

Mark on the wall the centre of the duct hole A.

2.

Use this centre to cut an opening through the wall 117mm dia, with a slight
fall to the exterior.

3.

Fit the wall duct (WD100), not supplied, and mortar into place.

If installing on a wall (flush mounting)

1.

Mark on the wall the centre of the duct hole A, and drill a pilot
hole through both walls at a slight downward angle.

2.

Use the centre to mark a rectangular hole for the inner wall using the
dimensions A.

3.

Cut the rectangular hole through the inner wall.

4.

Go outside and cut a 117mm-diameter hole in the outer wall using the small
hole as the centre.

5.

Measure the wall thickness.
Cut the wall duct (WD100), not supplied, so that it is 64mm less than the
wall thickness.

If installing in a ceiling (surface mounting)

This method requires a space above the ceiling, such as a loft or attic, to provide
access for 100mm internal diameter ducting.

1.

Mark on the ceiling the centre of the duct hole A, avoiding ceiling joists and
buried cables etc.

2.

Cut a 117mm-diameter hole using the marked centre.

If installing in a ceiling (flush mounting)

For 100mm diameter ducting:
1.

Mark a rectangular hole using the dimensions B.

2.

Cut the hole, avoiding ceiling joists and buried cables etc.

For flat ducting:

This fan can be installed within a 47mm void without the circular spigot 7
(Fig.E). Flat ducting adapter kit (FDA) available.

Preparing the fan for installation

1.

Remove the front cover 2 (Fig.C)

2.

Fit the foam tape !™ supplied around the circular spigot 7 (Fig.E).

3.

Remove the electrical cover 5 (Fig.E). The impeller can be removed to
ease access (if required)

. This is a "push-on/pull-off" assembly.

Setting the fan speed

DX200T / CF20 / CF20T Only (Fig.D)
4.

The correct condensation control speed (CF20/CF20T) or operating speed
(DX200T) should be selected to suit the room size in which the fan is to be
installed. Slide the switch X to the required position. Please note that the
fan is factory set to “Position 2”.

5.

Switch Position

Size / Room Volume (m

3

)

1

Large (34 and above)

2

Medium (28 – 34)

3

Small (less than 28)

Setting the trickle speed

DX200T / CF20 / CF20T Only (Fig.D)
6.

The fan can be set so that it provides constant trickle extraction. Slide the
switch Y to the required position. Please note that the fan is factory set to
“Position 0”.

7.

Switch Position

Setting

0

Trickle extraction OFF

I

Trickle extraction ON

Setting the time delay start

DX200T / CF20T Only (Fig.D)
8.

The fan can be set so that there is a 2-minute delayed start to its
operation when used with an external on/off switch. Slide the
switch Z to the required position. Please note that the fan is
factory set to “Position 0”.
Switch Position

Setting

0

Time delay start OFF

I

Time delay start ON

Mounting the fan on a wall or ceiling (surface mounting)

1.

Place the ducting into the hole and align to the required position. If wall
mounting, ensure that the ducting slopes down and away from the fan

2.

Mark the positions of the three fixing holes A in Fan box 6 (Fig.E).

3.

If wall mounting, drill three holes 5.5mm diameter for wall plugs (supplied).
If ceiling mounting B , use appropriate fasteners (not supplied).

4.

Cut out the cable inlet hole, if required, in the surround 0 and slit the cable
grommet. Slide the surround 0 over the fan box 6.

5.

Pass the electrical cables into the fan box 6 through the rear cable inlet
hole and surround, and re-fit the cable grommet.
Ensure that cable grommet is in place and a tight fit.

6.

Offer the fan box 6 up to the wall or ceiling. Ensure the circular spigot 7
enters the ducting.

7.

Fix the fan box 6 to the wall using screws 8 or to the ceiling using
appropriate fasteners (not supplied).

If mounting in a wall (flush mounting)

The surround 0 is not required. Fit the ducting to the circular spigot 7.

If the hole size is as recommended:
1.

Assemble the three fan body clamps 9 to the fan box 6 using screws 8.

2.

Slit the cable grommet. Pass the electrical cables into the fan box 6
through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.

3.

Offer the fan box 6 up to the wall.

4.

Tighten up the three screws 8 until the fan is clamped to the inner wall.
The fan body clamps 9 will rotate to an automatic stop position. DO NOT
OVERTIGHTEN
.

If the hole size is larger than recommended i.e.: larger than the flange on the
fan box
6

6 (Mostly relating to “retro-fit” installations):

1.

The fan body clamps ARE NOT suitable. Construct a wooden frame of
INTERNAL dimensions 203 x 233mm. Depth should be at least 50mm. Fit the

1. READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION.
2. INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS (UK), LOCAL OR APPROPRIATE

REGULATIONS (OTHER COUNTRIES). IT IS THE INSTALLER’S RESPONSIBILITY TO ENSURE THAT THE APPROPRIATE

BUILDING CODES OF PRACTICE ARE ADHERED TO.

3. A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS.
4. THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING
5. CHECK THAT THE ELECTRICAL RATING SHOWN ON THE FAN MATCHES THE MAINS SUPPLY.
6. WARNING: THESE APPLIANCES MUST BE EARTHED.
7. SITE AWAY FROM DIRECT SOURCES OF HEAT (I.E.: GAS COOKERS OR EYE-LEVEL GRILLS) AND NOT WHERE

AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 50˚C.

8. WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE, PRECAUTIONS MUST BE TAKEN TO

AVOID THE BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE FUEL BURNING APPLIANCE.

9. ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS (CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING

ETC) ARE TAKEN WHEN INSTALLING AND MAINTAINING THIS FAN.

10. GENERAL GUIDANCE FOR SITING THE FAN SEE “FIG. G”. ALWAYS SITE FAN AS HIGH AS POSSIBLE
11. IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST

BE FITTED AS CLOSE AS POSSIBLE TO THE FAN.

GB

IMPORTANT

Advertising
This manual is related to the following products: