Ancillary Options
For speed and ease of
Installation, your installation may
require some of the Ancillaries
listed below:

WD100

Wall Duct

CFWG100 Wall Grille
FDA

Flat Duct Adaptor Kit

XCT100

Condensation Trap

DGW/B

Air Replacement Door
Grille

SP100

Spigot Plate

XAA

Air Brick Adaptor

VC10

Vent Cowl

WT10

Termination Ducting
Kit

XF/FM

Flat Ducting
(Plastic/Metal)
(Plastic 234 x 29mm
Metal 230 x 25mm)

VK10

Wall Vent Kit

FD100

Flexible Ducting

WDC5

Worm Drive Clips

XCMK

Ceiling Mounting Kit

XBP

In-Line Back Draught
Shutter

EFT

Easy Fit Termination
Kit

GMK

Glass Mounting Kit

PDXGF

Grease Filter

Listed below are some of the
spares available. See back page
of this booklet for ordering details:

41520SK Fixing kit (Entire kit)
41528SK Circular Spigot (Entire

Range)

41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/

DX200T)

41782SK PCB Assy (DX200T)
41735SK PCB Assy (CF20)
41736SK PCB Assy (CF20T)
41737SK Front Cover c/w Baffle

(DX200)

41738SK Front Cover c/w Baffle

(DX200T)

41739SK Front Cover c/w Baffle

(CF20/CF20T)

41740SK Surround Moulding

(Entire Range)

41741SK Pull cord assembly

(CF20/CF20T)

41742SK Impeller (Entire

Range)

Accessoires en option
Pour une installation rapide et
facile, il est préconisé de se munir
des accessoires figurant sur la
liste ci-dessous :

WD100

Conduit mural

CFWG100 Grille murale
FDA

Kit d'adapteur de
conduit plat

XCT100

Trappe de
condensation

DGW/B

Grille de porte de
remplacement d’air

SP100

Plaquette pour ergot

XAA

Adaptateur de brique
perforée

VC10

Capuchon d’évent

WT10

Kit de terminaison de
conduit

XF/FM

Conduit plat
(Plastique/Métallique)
(Plastique 234 x 29 mm
Métallique 230 x 25 mm)

VK10

Kit pour évent mural

FD100

Conduit flexible

WDC5

Colliers à serrage par
vis sans fin

XCMK

Kit pour montage au
plafond

XBP

Obturateur de
refoulement en
ligne

EFT

Kit de terminaisons à
encliqueter

GMK

Kit de pose sur une
vitre

PDXGF

Filtre de graisse

Liste de quelques pièces de
rechange : Pour la commande,
prière de se reporter à la dernière
page de cette notice :

41520SK Kit de fixation (Kit

complet)

41528SK Ergot circulaire

(gamme complète)

41731SK Moteur (DX200)
41733SK Moteur (CF20/CF20T/

DX200T)

41782SK Carte imprimée

(DX200T)

41735SK Carte imprimée

(CF20)

41736SK Carte imprimée

(CF20T)

41737SK Couvercle avant avec

chicane (DX200)

41738SK Couvercle avant avec

chicane (DX200T)

41739SK Couvercle avant avec

chicane (CF20/CF20T)

41740SK Moulure de cadre

(gamme complète)

41741SK Ens. interrupteur à

cordon (CF20/CF20T)

41742SK Hélice (gamme

complète)

Zubehör
Die unten aufgeführten Produkte
unterstützen eine schnelle und
problemlose Installation:

WD100

Wandrohr

CFWG100 Wandgitter
FDA

Flachrohr-Adapter

XCT100

Kondensationsfalle

DGW/B

Luftaustauschtürgitter

SP100

Zapfenplatte

XAA

Luftziegel-Adapter

VC10

Lüftungskappe

WT10

Bausatz für
Rohrabbruch/
Rohrabschluss

XF/FM

Flachrohr
(Kunststoff/Metall)
Kunststoff 234 x 29 mm,
Metall 230 x 25 mm

VK10

Bausatz für
Wandlüftungs

FD100

Flexibles Rohr

WDC5

Schneckenantriebs-
klemmen

XCMK

Bausatz für
Deckenmontage

XBP

In-Line-
Durchzugsklappe für
die Rückseite

EFT

„Easy Fit" Bausatz für
Rohrabbruch/
Rohrabschluss

GMK

Bausatz für
Glasmontage

PDXGF

Fettfilter

Unten aufgeführt sind einige
Ersatzteile. Auf der Rückseite
dieses Hefts finden Sie
Einzelheiten über die Bestellung:

41520SK Befestigungsbausatz

(gesamter Bausatz)

41528SK Rundzapfen

(gesamtes Sortiment)

41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/

DX200T)

41782SK Flachbaugruppe

(DX200T)

41735SK Flachbaugruppe

(CF20)

41736SK Flachbaugruppe

(CF20T)

41737SK

Frontabdeckung C/W
Ablenkung (DX200)

41738SK

Frontabdeckung C/W
Ablenkung (DX200T)

41739SK Frontabdeckung C/W

Ablenkung (CF20/CF20T)

41740SK Einfassungsform

(gesamtes Sortiment)

41741SK Zugschnur

(CF20/CF20T)

41742SK Gebläserad

(gesamtes Sortiment)

Accessoireopties
Voor snelheid en gemak van
installatie is het mogelijk dat u
sommige van de onderstaande
accessoires nodig heeft.

WD100

Muurdoorvoer

CFWG100 Muurrooster
FDA

Adapterkit voor plat
kanaal

XCT100

Condensaatvanger

DGW/B

Deurrooster voor
luchtverversing

SP100

Luchtinlaatplaat

XAA

Adapter voor
gaatsteen

VC10

Uitlaatkap

WT10

Muurdoorvoerset

XF/FM

Plat kanaal
(plastic/metaal)
(Plastic 234 x 29mm
Metaal 230 x 25mm)

VK10

Muuruitlaatset

FD100

Flexibele slang

WDC5

Schroefdraadklemmen

XCMK

Plafondmontagekit

XBP

Gealigneerde
achterste tochtklep

EFT

Gemakkelijk te
monteren aansluitingset

GMK

Glasmontagekit

PDXGF

Oliefilter

Hieronder vindt u een lijst van
verkrijgbare reserveonderdelen.
Verwijs naar de achterste pagina
voor het bestellen ervan.

41520SK Montageset (volledig

set)

41528SK Ronde luchtinlaat

(volledige reeks)

41731SK Motor (DX200) **
41732SK Motor (DX200T) **
41733SK Motor (CF20/CF20T/

DX200T)

41734SK PCB montage

(DX200T)

41735SK PCB montage (CF20)
41736SK PCB montage

(CF20T)

41737SK Bovendeel

ventilatorhuis met
schermplaat (DX200)

41738SK Bovendeel

ventilatorhuis met
schermplaat (DX200T)

41739SK Bovendeel

ventilatorhuis met
schermplaat
(CF20/CF20T)

41740SK Lijstwerk voor

montageplaat
(volledige reeks)

41741SK Trekkoordmontage

(CF20/CF20T)

41742SK Rotor (volledige

reeks)

GB

F

D

NL

wooden frame into the internal wall and make good the hole.

2.

Offer the fan box 6 up to the wall.

3.

Screw the fan box 6 to the wooden frame using the slots in the flange
(screws not supplied).

If mounting in a ceiling (flush mounting)

1.

The surround 0 is not required.

2.

Insert the fan box 6 into the hole and mark four positions using the slots in
the flange B.

3.

Remove the fan box 6 from ceiling and fit the four ceiling clips (supplied)
over the edge of the hole, so that the clips align with the marks on the ceiling B.

4.

Drill 4 pilot holes into the ceiling through the hole of each clip, ensuring not to
damage the clip.

5.

Fit the ducting to the circular spigot 7.

6.

Offer the fan box 6 up to the ceiling.

7.

Slit the cable grommet. Pass the electrical cable into the fan box 6 through

the front cable inlet hole.

Ensure cable grommet is in place and a tight fit.

8.

Using the screws !¡ (Fig.B), fix the fan box flange to the ceiling clips.

Terminating the ducting

Fit an outer grille (such as CFWG100, not supplied in the DX200/DX200T)
to the outer wall. For ceiling mounting, use appropriate ancillaries (not
supplied).

Wire the electrical connections

WARNING! THIS APPLIANCE MUST BE EARTHED
1.

Isolate the electricity supply and remove all fuses.
The terminal block will accept cable up to 1.5mm

2

2.

Use a double-pole isolating switch with a minimum contact gap of 3mm in
both poles.

3.

Use suitably rated 3-core or 4-core cable dependant on application.

4.

Remove the retaining screws of the terminal cover, if still in position.

5.

Wire the fan as shown in F using the cable clamp provided. Check fan
model to diagram.
DX200: “LH” =Live (High Speed)/ “LL” = Live(Low Speed)

6.

Replace the terminal cover 5 and fasten the retaining screws.

7.

See section on “User adjustments” if you wish to use settings other than
those that have been factory set.

8.

Refit the front cover(Fig.C).
Connect the cable from the isolating switch to electrical supply wiring, and
re-check installation.

10. Refit fuses before turning on electricity supply.
11. For fixed wiring circuits, the protective fuse for the appliance must not

exceed 5A.

For Australia Only
CF20
– Connection to the supply - flexible 3-core cable with 3 pin plug top for
insertion into an approved 10A wall mounted surface switch with at least 3mm
clearance between contacts.

ALL OTHERS – Permanently connected to the supply and a remote switch controls
operation. They should be directly wired to the supply through an approved 10A wall
mounted surface switch with at least 3mm clearance between contacts.

User adjustments

Before making any adjustments, isolate the fan completely from the mains
supply, check specification below to see which features apply to your fan.
1.

Remove the front cover and replace after adjustment (Fig. C)

DX200

There are no user adjustments for this fan.

DX200T

1.

The timer over-run period can be adjusted between approximately 30
seconds and 20 minutes. Use an electrician’s screwdriver and turn screw “T”
(Fig.D), clockwise to increase time, anti-clockwise to decrease. (Factory
preset to approximately 10 minutes)

CF20

1.

The humidity setting is adjustable between approximately 50% and 90%
relative humidity. Use an electrician’s screwdriver, and turn screw “RH”
(Fig.D), clockwise to increase the relative humidity setting and anti-clockwise
to decrease. (Note: the fan is more sensitive at 50% RH than at 90% and is
factory preset to approximately 70%).

CF20T
1.

The timer over-run period can be adjusted between approximately 30
seconds and 20 minutes. Use an electrician’s screwdriver and turn screw “T”
(Fig.D), clockwise to increase time, anti-clockwise to decrease.

2.

The humidity setting is adjustable between approximately 50% and 90%
relative humidity. Use an electrician’s screwdriver, and turn screw “RH”
(Fig.D), clockwise to increase the relative humidity setting and anti-clockwise
to decrease. (Note: the fan is more sensitive at 50% RH than at 90%).

Using the fan

DX200

Operate the fan using the external on/off switch. Repeat to switch off.
The fan speed is pre-set by the installer to either high or low speed. (If a change
over switch has been installed then the user can switch between high speed and
low speed.)

DX200T

Operate the fan using the external on/off switch. Repeat to switch off.
When the switch is turned off, the fan continues to operate for the selected over-
run timer period. Top Light “I” is lit when the external on/off switch is switched on.
The fan speed is pre-set by the installer to either high, medium or low speed.

Time delay start feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is
switched on using the external on/off switch.

CF20 / CF20T

Switched Operation
The fan can be wired with a separate on/off switch. Fan operates at condensation
speed when switched on. Top “Light I” is lit when the separate on/off switch is
switched on. When switched off, the fan will continue to operate if the humidity level
exceeds the set level. CF20T only: When switched off, the fan continues to operate
at condensation speed for the adjustable timer over-run period.

Condensation Operation
The fan operates at condensation control speed, when the relative humidity
exceeds the set level, and turns off when the humidity drops.

Boost Operation
The integral pull cord switch switches the fan to run at high speed. Bottom “Light
II”
is lit when the fan is operating at high speed.
Note: If the separate on/off switch and integral pull cord are both on, then Lights “I”
and “II”
will both be lit and the fan will run at high speed.

CF20T only

Time delay start feature on or off
This is set by the installer to provide a 2-minute time delay start when the fan is
switched on using a separate on/off switch.

Cleaning

Before cleaning, isolate the fan completely from the mains supply
Only clean the external surface of the fan, using a damp lint free cloth.
Do not use strong detergents, solvents or chemical cleaners
Allow fan to dry thoroughly before use.
Apart from cleaning, no other maintenance is required.

Key See Diagram E

1.

Baffle Plate

2.

Front Cover

3.

Impeller

4.

Fixing Screws

5.

Terminal Cover

6.

Fan Box

PLEASE LEAVE THIS LEAFLET WITH THE FAN FOR THE BENEFIT OF THE
USER

7.

Circular Spigot

8.

Clamp screws and wall plugs - 3 off

9.

Fan Body Clamps – 3 off

10. Surround
11. Ceiling Screws 25mm long 4 off (Diagram B)
12. Foam Tape

Advertising
This manual is related to the following products: