Electrical connection
Any electrical work required to install this

appliance should be carried out by a qualified

electrician or competent person.

WARNING!

This appliance must be earthed.

The manufacturer declines any liability

should this safety measure not be

observed.
Before switching on, make sure the electricity

supply voltage is the same as that indicated

on the appliance’s rating plate.
IMPORTANT!
Information on the electrical connection is

given on the rating plate on the inner edge

of the appliance door.
The appliance is supplied with a 13amp plug

fitted. In the event of having to change the

fuse in the plug supplied, a 13amp ASTA

approved (BS1363/A) fuse must be used.
Should the plug need to be replaced for any

reason, proceed as described below.
The wires in the mains lead are coloured in

accordance with the following code:
Green and Yellow ..............................- Earth

Blue ....................................................- Neutral

Brown..................................................- Live

The wire coloured

green and yellow must

be connected to the

terminal marked with

the letter «E» or by the

earth symbol

or

coloured green and yellow.

GREEN &YELLOW

BROWN

CORD CLAMP

BLUE

13

A

E

N

L

The wire coloured blue must be connected to

the terminal marked «N» or coloured black.
The wire coloured brown must be connected to

the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray

strands of wire present and the cord clamp

must be secure over the outer sheath.

WARNING!

A cut off plug inserted into a 13 amp socket

is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of

safely. Should the appliance power supply

cable need to be replaced, this must be

carried out by our Service Force Centre.
The power supply cable must be easily

accessible after installing the appliance.
Permanent connection
In the case of permanent connection it is

necessary that you install a double pole switch

between the appliance and the electricity

supply (mains), with a minimum gap of 3mm

between the switch contacts and of a type

suitable for the required load in compliance

with the current electrical regulations.

The switch must not break the yellow and

green earth cable at any point.