Xantrex Technology PROSINE PS3.0 User Manual

Page 74

Advertising
background image

Prosine 2.5/3.0 Installation & Operation Guide

57

Section 5: Operation

Input Voltage: The Prosine inverter/charger operates from an input voltage ranging from 10 volts to
16 volts, (20 to 32 volts on 24V models) and peak performance occurs when voltage is in the range of
12 volts to 13 volts (24 to 26 volts on 24V models) as shown in the following table.

Prosine Operating Voltage Limits

Operating
Condition

Voltage Range

12-Volt System

Voltage Range

24-Volt System

Normal

10V - 16V

20V - 32V

Peak Performance

12V - 13V

24V - 26V

High Voltage Alarm

LED On

>15.5V

>31V

Unit Shuts Down

>16V

>32V

Low Voltage Alarm

LED Flashes

10.5

V

21V

Unit Shuts Down

≤10.0

V

≤20

V

Unit Restarts

≥12.3

V

≥24.6

V

Advertising
This manual is related to the following products: