Warning: fire and explosion hazard – Xantrex Technology 200 User Manual

Page 52

Advertising
background image

Maintenance

4-6

975-0057-01-01

Recharging with a Generator’s Regulated 12 V DC
Outlet

Refer to the Owner’s Guide accompanying your generator for

detailed instructions on connecting the generator to a unit like

the

XPower Powerpack

.

You can recharge the battery of the

XPower Powerpack

using

a generator in several ways:

Using the AC Charger to recharge the

XPower

Powerpack

from a generator is possible, but would

require extended generator running time.

Using a generator which has an auxiliary regulated 12 V
DC output designed for charging 12 V batteries. Most
generators are equipped with them. Use this power
source for faster charging.

Using a generator with a regulated 12 V DC lighter
socket. Follow the connection instructions in

“Recharging with the DC Charging Cable” on page 4–4

.

Most of the

XPower Powerpack

’s battery capacity will be

recharged in a few hours.

WARNING: Fire and Explosion
Hazard

The generator output must be intended for battery
charging and have an output of 15 V or less. An
unregulated output or one that exceeds 15 V DC
can damage the battery.

This may lead to accumulations of hydrogen,
causing exposure to fire and explosion hazard.

Note

: Battery Charge (%) indicator is only accurate when

the

XPower Powerpack

has been disconnected from all

appliances and all charging sources for fifteen minutes.