Step two – install an optional ir sensor, Step three – install the kp 1 in the wall – Xantech YiAK-K1000-01A User Manual

Page 4

Advertising
background image

Step Two – Install an Optional IR Sensor

If you are installing the optional IR sensor, you also need to prepare the sensor’s ribbon
cable. The recommended Xantech 490-00 Micro Link comes with a 7-foot long, 3-con-
ductor ribbon cable. Trim the ribbon cable to 3 or 4 inches. Strip the wire ends 1 to
1-1/2 inches, then fold each bare end over itself twice and twist it. This creates a slightly
thicker wire to connect to the KP 1‘s IR Sensor Terminal Block

4. Break out the

IR Sensor Cutout

5 on the front of the KP 1 by gently pressing out, and insert the

Micro Link sensor through the hole from the front, cable end first. Install the sensor’s
nut on the threaded body of the sensor before connecting the ribbon cable to the
KP 1’s terminal block. Tighten the nut to secure the sensor in its cutout.

Carefully connect the bare ends of the sensor’s three wires to the KP 1 Terminal
Block
¢ as shown in Figure 2 and Wiring Chart 2. Loosen the set screw for each ter-
minal position, insert the end of the bare wire into the hole directly under the corre-
sponding set screw, and tighten the set screw, making sure that no wires touch each
other or other terminals. If a different compatible IR sensor is used, match the wire
color used to the specific circuit function. Then connect the wires to the KP 1 Terminal
Block
¢ in accordance with Wiring Chart 2.

Position on KP 1

Position on Micro Link

Circuit Function

Terminal Block

Ribbon Cable

Right Middle

+12

Volts

Middle

Red or White Stripe on

IR Signal (Output

Outside of Ribbon

of Micro Link)

Left

Opposite to Stripe

Ground

Wiring Chart 2

No other connections are required, as the terminal block is internally connected to the
KP 1’s RJ-45 Connector £ for connections to the PA 4000 and onward to other IR-
controlled devices as applicable.

Step Three – Install the KP 1 In the Wall

Although the KP 1 is designed to fit into a standard single-gang electrical junction box
or plaster ring, always check the fit before cutting into a wall. Follow these guidelines
for optimal placement of the KP 1:

CAUTION: THE ELECTRICAL JUNCTION BOX IN WHICH THE KP 1 IS MOUNTED
MUST BE DEDICATED TO LOW-VOLTAGE CONTROL SYSTEM APPLICATIONS. MAKE
SURE THAT NO AUDIO/VIDEO OR AC MAINS WIRING PASSES THROUGH OR TER-
MINATES IN THIS BOX!

If you install the optional IR sensor, avoid placing the KP 1 in an area subject to poten-
tial interference with the IR signal.
Locate the KP 1 at least 4 inches from a dimmer switch, or install it inside a metal box
rather than plastic, as the dimmer switch may generate electronic noise that might
interfere with the KP 1.
The KP 1 may be installed in a multi-gang junction box with other low-voltage controls.
Please refer to Figure 3 for guidance in installing the KP 1 into a junction box and
attaching a Decora-style cover plate.

Gently place the KP 1 in the junction box or plaster ring and attach it by inserting the
supplied mounting screws through the Mounting Screw Slots ™ of the KP 1
until it is aligned correctly and tighten the screws.
Attach a Decora-style cover plate (not included) by placing the screws provided
with the cover plate through the plate’s holes and into the KP 1’s Cover Plate
Screwholes
¡. Hand-tighten the screws so that the cover plate is secure, taking care
so as not to overtighten and break the cover plate. Although any color or compatible
style of wall plate may be used with the KP 1, the KP 1 itself should not be painted,
in order not to cover the printed button labels.

490-00

IR Receiver

Red (or White)
Stripe

OUT

+12V

GND

7’ Ribbon Cable

Copyright 2000 Xantech Corporation

a IR Remote Control Output
b MR On/Off Command Switch
c Remote IR Sensor Inputs
d Remote Keypad Inputs
e Bridge 1 Amplifier Mode Switch
f Bridge 2 Amplifier Mode Switch
g Power Control Mode Switches
h Volume/Output Level Controls

Step Four – Connect the KP 1 to the PA 4000

• When the PA 4000 is used in the Normal mode, feeding four pairs of speakers, con-

nect the cable from each KP 1 to the Remote Keypad Input

d corresponding to

the proper speaker channel for that room.

• When the PA 4000 is used in one of the Bridged modes, connect the cable from the

KP 1 to the Remote Keypad Input

d corresponding to the lower numbered jack

for the pair of channels being bridged. Thus, when Output Channels 1 and 2 are
bridged, connect the KP 1 cable to the Remote Keypad Input

d connector for

Channel 1. When Channels 3 and 4 are bridged, connect the KP 1 cable to the
Remote Keypad Input

d connector for Channel 3.

• The proper Remote Keypad Input

d connections are determined by whether

the amplifier channels are used in their Normal mode or if they are bridged. Use of a
separate input source for Channel 3 does not impact the keypad connections.

• When a KP 1 is connected to any Remote Keypad Input

d, the Power Control

Mode Switch

g for that channel must be placed in the far right position, under

the words “ON/KEYPAD” to enable the KP 1’s Power Button

3 to turn on the

PA 4000.

AC/DC

TRIG.

BRIDGE 2

BRIDGE 2

DN

CH4

CH3

CH2

CH1

CH3

CH1

KEYPAD IN

VOLUME

REMOTE

CONTROL OUT

MR ON/OFF

COMMAND

AMP MODE

ON/

KEYPAD

MUSIC
SENSE

AC/DC

TRIG.

ON/

KEYPAD

MUSIC
SENSE

AC/DC

TRIG.

ON/

KEYPAD

MUSIC
SENSE

AC/DC

TRIG.

ON/

KEYPAD

MUSIC
SENSE

ON

OFF

NORMAL

CH3/4

NORMAL

CH1/2

OFF

UP

DN

UP

DN

UP

DN

UP

CH4

BRIDGE 1

CH2

BRIDGE 1

CH3

SEPARATE

ON

CH4

CH1

REMOTE IR SENSOR IN

CH3

CH2

CH 3 IN

MAIN

3-30V

AC/DC

TRIGGER

INPUT

CH4

CH3

CH2

CH1

BRIDGE 2

BRIDGE 1

CH4

BRIDGE 2 CH3

CH2

BRIDGE 1 / CH1

POWER CONTROL MODE

a

b

c

d

e

f

g

h

Front
Panel

Decorator
Cover
Plate &
2 Screws
(not included)

1/8" x 3/4" Machine
Screws (2) (included)

Wallboard

J-Box

RJ-45
Connector
(cable
not shown)

Figure 2

Figure 3

Rear of PA 4000

Advertising