9 supply air blower performance -dee, Deg048 w/ belt drive & side duct, Able 9 or – York SUNLINE PLUS D1EE036 User Manual

Page 12: 9 or

Advertising
background image

036-21411-002-A-0204

12

Unitary Products Group

TABLE 9: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG048 W/ BELT DRIVE & SIDE DUCT

1

2

MODEL

DEE/DEG

AIR

FLOW

CFM

AVAILABLE EXTERNAL STATIC PRESSURE - IWG

3

0.20

0.30

0.40

0.50

0.60

0.70

0.80

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

048

2000

843

860

880

925

919

1005

956

1065

993

1145

1030

1195

1067

1235

1900

817

775

854

850

893

920

930

995

970

1065

1008

1125

1046

1170

1800

790

700

828

760

867

840

906

905

944

980

985

1040

1025

1100

1700

-

-

802

670

840

745

881

815

920

900

961

970

1001

1030

1600

-

-

-

-

818

665

858

740

898

820

940

890

980

950

1500

-

-

-

-

-

-

842

695

882

755

922

835

962

895

1400

-

-

-

-

-

-

833

650

867

705

904

765

942

820

1300

-

-

-

-

-

-

-

-

858

665

893

725

932

785

1200

-

-

-

-

-

-

-

-

847

640

880

680

916

730

MODEL

DEE/DEG

AIR

FLOW

CFM

AVAILABLE EXTERNAL STATIC PRESSURE - IWG

3

0.90

1.00

1.10

1.20

1.30

1.40

1.50

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

RPM

WATTS

048

2000

1103

1270

-

-

-

-

-

-

-

-

-

-

-

-

1900

1085

1210

-

-

-

-

-

-

-

-

-

-

-

-

1800

1064

1145

1102

1180

-

-

-

-

-

-

-

-

-

-

1700

1040

1075

1081

1115

1121

1140

-

-

-

-

-

-

-

-

1600

1020

1005

1060

1050

1100

1085

-

-

-

-

-

-

-

-

1500

1003

945

1044

995

1086

1035

-

-

-

-

-

-

-

-

1400

982

880

1024

920

1067

965

1107

1000

-

-

-

-

-

-

1300

970

835

1010

870

1053

920

1099

960

-

-

-

-

-

-

1200

953

780

992

815

1034

855

1080

905

-

-

-

-

-

-

1.

230/460/575 Volts

2.

For 208 Volts multiply values by 0.95.

3.

Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to Table 12 for resistance values on applications
other than gas / electric units with side duct airflows.

Advertising
This manual is related to the following products: