Inst allation – Zephyr EBO-E36ASX User Manual

Page 12

Advertising
background image

12

19. Connect ducting to transition. Seal with duct tape.

Do not use duct smaller than the transition.

For Ductless - recirculating - installations only:

provide and install a duct to connect hood transition to

deflector (the deflector is available as an extra kit).

20. Electrical connection

WARNING

Electrical Shock Hazard

Warning: Turn off power circuit at the service panel

before wiring this unit.

120 VAC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS FITTED WITH AN ELECTRICAL

JUNCTION BOX WITH 3 WIRES, ONE OF WHICH

(GREEN/YELLOW) SERVES TO GROUND THE

APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC

SHOCK, THE GREEN AND YELLOW WIRE MUST BE

CONNECTED TO THE GROUNDING WIRE IN YOUR

HOME ELECTRICAL SYSTEM, AND IT MUST UNDER

NO CIRCUMSTANCES BE CUT OR REMOVED.

Failure to do so can result in death or electrical

shock.

Facing the front of the range hood, remove the left

knockout and the Junction box cover and install the

conduit connector (cULUS listed) in junction box.

knockout

J-Box

cover

Run 3 wires; black, white and green ,according to the

National Electrical Code and local codes and

ordinances, in 1/2" conduit from service panel to

junction box.

J-Box cover

Conduit

Connect black wire from service panel to black or red in

junction box, white to white and green to green-yellow.

Close junction box cover.

21. Note: disregard this step if the hood has been fitted

with an internal blower.

Purchase and install a In-line blower (see paragraph

„Before installing the hood - Parts not supplied“ for

model reference).

22. For Ductless (recirculating) installations

Install one charcoal filter (available as an extra kit).

23. Install filters.